The following entries appear in the WORKING-STORAGE SECTION: 01 DATE-TODAY. 05 YY PIC XX VALUE "90". 05 MM PIC XX VALUE "12". 05 DD PIC XX VALUE :31". 01 DATE-EDIT PIC XX/XX/XX. MOVE DATE-TODAY TO DATE-EDIT. (a) 901231 (b) 90/12/31 (c) 31/12/90 (d) 311290
4 8551How many bytes will be allocated for the following record description entries? 01 REC-A. 05 A PIC S9(4). 05 B PIC XXXBXXX. 05 C PIC ____9.99. 05 D PIC S9(5) COMP-3. 05 E PIC 9(3) COMP.
16 25509What is wrong with the following data declaration? 01 W-DATE PIC X(6). 05 DD PIC 99. 05 MM PIC 99. 05 YY PIC 99. (a) Nothing is wrong. (b) Under W-DATE all level 05 items are having a PIC 99 but level 01 has PIC X(6). (c) PIC can't be specified for a group item. (d) DD, MM, and YY are invalid datanames.
6 13492What is the output generated by the following code? 01 GRP-I. 05 SUBFLD1 PIC XX VALUE "AB". 05 FILTER PIC X(6) VALUE SPACES. 01 GRP-2 REDEFINED GRP-1. 05 SUB-FLD2 PIC XX. 05 SUB-FLD3 PIC XX. 05 FILTER PIC X(4). IF SUB-FLD1 NOT = SPACES DISPLAY "SUBFLD1" MOVE "ABBCCD" TO GRP-1 IF SUB-FLD3 = SPACES DISPLAY "SPACES" ELSE DISPLAY "SUBFLD3" DISPLAY "END" ELSE DISPLAY "SPACES" DISPLAY "END". (a) SUBFLD1 SUBFLD3 END (b) SPACES END (c) SUBFLD1 END (d) SUBFLD1 SPACES
7 1024288 level entry is used for (a) data items in WORKING-STORAGE SECTION (b) items with RENAMES clause (c) condition-names (d) None of the above
5 10890ZEROES and SPACES are _______ constants (a) Figurative (b) Numeric (c) Non-numeric (d) Alphabete
4 9160COMPUTE X = A * B - C * D and COMPUTE X = (A * B) - (C * D) (a) Are not the same (b) Are same (c) Syntactically wrong (d) Will yield a run time error
1 6461OCCURS clause is used in the DATA DIVISION on data names at (a) 01 level (b) 77 level (c) 88 level (d) any level from 02 to 49
13 20785Consider the following COBOL entries: 05 X PIC 99 VALUE 10. SUBTRACT 20 FROM X. The resultant value of X wil be
7 15609Consider the following COBOL entries 05 X PIC 99 VALUE 10. ADD 40 X TO X. COMPUTE X = 3 * X - 40. The result in X is
12 19332given the following piece of code: CALL SUB-PGM USING A, B, C. CALL SUB-PGM USING A, C, C. (a) Both CALL statements will always produce same result. (d) Both CALL statements may produce different result. (c) Compile-time error because SUB-PGM is a dataname. (d) Compile-time error because A, B, C are used twice.
2 8615The hierarchy of the execution of logical operators is (a) NOT AND OR (b) AND OR NOT (c) OR AND NOT (d) OR NOT AND
10 33366The order of precedence of arithmetic operators in an expression can be overridden with the use of (a) [] (b) () (c) {} (d) Any of the above
3 9978Which of the following files can be OPENed in all the 4 modes? The four modes are INPUT, I-O, OUTPUT and EXTEND. (a) INDEXED (b) RELATIVE (c) SEQUENTIAL (d) All of the above
7 15117Post New TCS Interview Questions
How to specify client field in Native Query?
Why dependency injection is used in java?
What does linear in ‘linear regression’ actually mean?
What is #include stdio h?
main difference between ac and dc?
Why did you decide to pursue your career at Office Depot?
What is catelog procedure and how many catelog procedure to use in one job?
Who owns sybase?
Explain what is information?
In how many ways, can one configure spring into an application?
What is the use of symbol // in jcl?
tan delta equation test on alternators
What is the difference between "using system.data;" and directly adding the reference from "add references dialog box"?
Will a steel cable become longer if it is heated while under load?
give the co-ordination number of nacl?