DG B-check,C-Check,D-check is depending upon the running
hrs.If the running hrs is not reached as mentioned.How to
conduct the DG checks.

Answers were Sorted based on User's Feedback



DG B-check,C-Check,D-check is depending upon the running hrs.If the running hrs is not reached as ..

Answer / omprakash

B. CHECK 250 HRS OR 6 MONTHS
C. CHECK 1000 HRS OR 1 YEAR
D. CHECK 1500 HRS OR 2YEARS

Is This Answer Correct ?    90 Yes 26 No

DG B-check,C-Check,D-check is depending upon the running hrs.If the running hrs is not reached as ..

Answer / neeraj

DG check can also be done after completion of period like 3
months 6 month and 12 months

Is This Answer Correct ?    71 Yes 23 No

DG B-check,C-Check,D-check is depending upon the running hrs.If the running hrs is not reached as ..

Answer / arunselva

A Check Daily check
B Check 250Hr to 300Hr or 6 Month
C Check 1000Hr or 1Year
D Check 1500Hr or 2Year

Is This Answer Correct ?    57 Yes 20 No

DG B-check,C-Check,D-check is depending upon the running hrs.If the running hrs is not reached as ..

Answer / ganesh singh

A-check Daily
B- check 300 hrs or 6 month All filter & lube oil change
C-check 1500 hrs or 1 yrs (Tapit setting)
D-check 5800 hrs or 2 yrs (HPIT seting)
E-check 10000hrs overhalling (crank
grinding,shaft,actuatoer etc)

Is This Answer Correct ?    36 Yes 6 No

DG B-check,C-Check,D-check is depending upon the running hrs.If the running hrs is not reached as ..

Answer / baskaran.r

the checks are depend on the running hrs. if it is not
reached means engine is not running ok.you can wait till the
running hrs reached. if the stoppage is long you can go
according preservation requirement by the manufacturars
recomendation

Is This Answer Correct ?    43 Yes 15 No

DG B-check,C-Check,D-check is depending upon the running hrs.If the running hrs is not reached as ..

Answer / lallan

HOW TO SCOPE IN A,B,C,D CHECK? PLZ DEFINE

Is This Answer Correct ?    17 Yes 4 No

DG B-check,C-Check,D-check is depending upon the running hrs.If the running hrs is not reached as ..

Answer / mayank sharma

DG Checks are depand upon running hours but if running hours is not reached then we should conducts checks as per the time duration as listed below :

A Check - daily
B Check - 300hrs. or 6 months( filter change, lube oil change)
C check - 1500 or 1 year(A+B checks+ injectors & turbo charger cleaning )
D Check - 5000 hrs. or 2 year( A+B+C Checks+ Tappid setting )

Is This Answer Correct ?    14 Yes 1 No

DG B-check,C-Check,D-check is depending upon the running hrs.If the running hrs is not reached as ..

Answer / pavan

If it is not reach the running hours.we can take the number
of days from its working.

Is This Answer Correct ?    26 Yes 14 No

DG B-check,C-Check,D-check is depending upon the running hrs.If the running hrs is not reached as ..

Answer / sk ajibar rahman

"A" - Daily Checks
"B" - 300 Hrs or 6 Months
"C" - 600 Hrs or 12 Months
"D" - 1200 Hrs or 24 Months

Is This Answer Correct ?    27 Yes 15 No

DG B-check,C-Check,D-check is depending upon the running hrs.If the running hrs is not reached as ..

Answer / biswajeet

the checks are depend on the running hrs. if it is not
reached means engine is not running ok.you can wait till the
running hrs reached. if the stoppage is long you can go
according preservation requirement by the manufacturars
recomendation

Is This Answer Correct ?    12 Yes 7 No

Post New Answer

More Electrical Engineering Interview Questions

Define ampere

0 Answers  


ganaretors A check B check and C check details

1 Answers  


what condition there autotransformer will fail?

2 Answers  


why C.T protection required for H.T.lines?

4 Answers  


we need a ntpc previous papers

0 Answers  






what is the working principle of a DG Set, Alternator, & exiter

0 Answers  


what reactive how to maintain

0 Answers  


what is difference between RCB,RCCB &RCBO?

3 Answers   ABB,


what is electricity

3 Answers   APGenco,


describe the phenomena of vacuum interruption in C.B

0 Answers  


What is the selection process of breakers. Can any one please give a formulation on same?

0 Answers   Sterling Wilson,


Please mention any books for electrical design load calculation for industrial,commercial(to select cable,breaker,bus bar,stator,)

1 Answers   C&S,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)