Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


what is "smart" in smart transmitter ?

Answers were Sorted based on User's Feedback



what is "smart" in smart transmitter ?..

Answer / rahul tope

Single module auto ranging
transmitter

Is This Answer Correct ?    9 Yes 3 No

what is "smart" in smart transmitter ?..

Answer / saravanakumar

Smart is an electronic circuit based on micro controller that is present in transmitter.

Is This Answer Correct ?    5 Yes 3 No

what is "smart" in smart transmitter ?..

Answer / whiteax

A sensor containing a processing device that performs spontaneous digital signal processing and conditioning when it receives multiplexed sensor inputs is called a Smart Sensor. When this input, after processing, algorithmic decision-making and actuating, becomes an output signal, the smart sensor behaves as a transmitter. This dual-function is why it is called a smart sensor/transmitter.

Is This Answer Correct ?    4 Yes 3 No

what is "smart" in smart transmitter ?..

Answer / abu maryam

The smart in smart transmitters mean its diagnostics ability

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Instrumentation Interview Questions

What is the relationship between the universal gravitational constant (G) and the acceleration due to gravity (g)?

3 Answers   APPSC,


how to test rotor &stator earth fault in turbine

1 Answers   Bhel,


Speedtronic system .

0 Answers   CCIE,


Define all the process Variable and state their unit of measurement. ?

0 Answers  


how to use one 4-20mA signal for two indicater or controller & give necessary precaution.

2 Answers  


what is the use of glycol filling in seal pot (or) condensate pot in instrument impluse line?

7 Answers  


Possible cause of IOP alarm in a DP transmitter: a: IOP-minimum b: IOP-Maximum

4 Answers  


Yokogawa dcs nodes advantages?

0 Answers   Petrochemicals,


what is reset windup in integral control?

6 Answers   Honeywell,


why we use -ve voltages in vibration prob?

1 Answers  


why 4-20 mA signal is preferred over a 0-10V signal

17 Answers   Sofcon,


Q- Why Phase tester is only used for checking AC not DC ?

1 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)