Answer Posted / rahul tope
Single module auto ranging
transmitter
| Is This Answer Correct ? | 9 Yes | 3 No |
Post New Answer View All Answers
The company where I am working, their is rosemount 5400 series radar type level transmitter, it is meant to show level of filled tank, but along with the level it is showing temperature also, so my question is how a onon-contact type radar type level transmitter can show temperature even if it does not have any contact with the fluid?
how to control pid
how pressurize drum calibrated ?
what is vibration a part of proceess variable? if vibration is a part variables then how we minimize the actual vibration on machine on load,? vision of instrumentation contrl plz ans me IPGDL interview question
What is difference between Ionization heat and bimetallic heat
What is Alpha & Beta fctors related to Orifice Plate & its relation with flow?
In bently nevada vibration monitoring system,what is the reason to maintain the Resistance of the probe + extension cable equal to 95 ohm? If possible explain the basic principle of measurement with detail electronic circuits.
what is cems analyzer explain with principle and drawing ?
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
PLEASE PROVIDE SAMPLES OF CHEVRON SKILL TESTS
Specify eight technical requirements that you would consider important, when deciding upon a particular control valve?
what is the input of digital counter during the the calibration time?
What is the difference between modbus,fieldbus & profibus
what are the steps I have to deal with?
Please can anybody help for control valve sizing step by step procedure?