Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


i am swathi, b.tech 4th year.
In smps(switched mode power supply)we are using
diodes,mosfets,igbts for controling of current.
And my question is why we did not use thyristors(scr)? it
is also act as a switch,then what is the drawback of scr as
compared to above transisters> if we use the scr,then what
is happening ? plz give reply as soon as possible bcoz i
am doing project on smps. plz frnds i want ans for
that. if anybody know the ans plz send to my e-mail
id /swathi.tadakapally@gmail.com/

Answers were Sorted based on User's Feedback



i am swathi, b.tech 4th year. In smps(switched mode power supply)we are using diodes,mosfets,igb..

Answer / nithi

SCR cannot be used due to the following reason.

1.we have to design commutation circuit for SCR.(this will
increase the complexity of the circuit)

2.cost of SCR is higher than MOSFET,TRANSISTOR & IGBT.

3.SCR is current controlled device .This will increase the
load on the triggering circuit.

4.The voltage drop & power loss in SCR is somewhat higher
than mosfet,igbt & transistor.

5.moreover,the switching frequency of the SCR is very low
(around 1khz).

so,I think it is better to use MOSFET,IGBT & TRANSISTOR as
a switching device in SMPS.OK............

Is This Answer Correct ?    19 Yes 3 No

i am swathi, b.tech 4th year. In smps(switched mode power supply)we are using diodes,mosfets,igb..

Answer / prasad,clp(power)

Hi dear this is prasad from clp (power)...we can use
thyristor(scr) but for scr we have to design firing angle
circuit separatly,we have to check whether scr is
triggering or turning on exatctly as per our requirements
or not and for high power applications it is better to
diodes,mosfet,igbts..in these we wont face firing angle
circuit design problems...bocz for the SCR firing circuit
is the heart hope so....

Is This Answer Correct ?    10 Yes 6 No

i am swathi, b.tech 4th year. In smps(switched mode power supply)we are using diodes,mosfets,igb..

Answer / g venkateswarlu

hi dear swathi,as per your question SCR act as switch but it is current controlled device and its operating frequecy is 400-500hz, voltage drop less than 2 volts,and its application are dc motor control and rectifier and inverter. where as MOSFET AND IGBT voltage control device and above nithi ans also correct

Is This Answer Correct ?    0 Yes 0 No

i am swathi, b.tech 4th year. In smps(switched mode power supply)we are using diodes,mosfets,igb..

Answer / anjun

hi swathi....its better to ask in GATE FORUM, where u will find correct ans......Anjun

Is This Answer Correct ?    0 Yes 2 No

i am swathi, b.tech 4th year. In smps(switched mode power supply)we are using diodes,mosfets,igb..

Answer / w

Yes u can use the SCR

Is This Answer Correct ?    1 Yes 8 No

Post New Answer

More Electrical Engineering Interview Questions

is earthing is necessary if we use armoured cable

1 Answers   ABB, Schwing Stetter, Siemens,


why the all high voltage transformers are in 11kv , 33kv , 66kv, 132kv like that

2 Answers   Bhel,


what is quality factor in series resonance circuit and calculate the factor of voltage magnification? how it happens?

0 Answers   BARC,


How to calculate no of EARTH PIT? Describe the formula as per IS standard?

0 Answers  


7. A resistance of 30 ohm is connected across 240v supply. If a resistance R ohm is connected in parallel with 30ohm resistor across the same supply, the current drawn becomes triple of original one The unknown resistor R is

2 Answers  


i have gear oil pump with single phase motor.some time its motor starts running in reverse direction rather than forward direction...whats the reason behind this issue. 1- either capacitor is week? 2- or winding is week?

0 Answers  


can we use HPSV LAMP in HPMV LAMP fixture ?and viseversa.

5 Answers   OPS,


whit is 33kv power 300*300 cable full current with formula

0 Answers  


what is the difference between LT and HT power supply?

26 Answers   Center One Mall, Central University, JSW, Siemens, Suzlon,


how did the differential relay work to protect the power transformer

4 Answers  


40 HP motor how many square mm size wire use for stator to motor & aluminium wire use ?

1 Answers   SSPL,


why is used for starters for staring motors?

6 Answers   Amrapali, L&T,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)