i am swathi, b.tech 4th year.
In smps(switched mode power supply)we are using
diodes,mosfets,igbts for controling of current.
And my question is why we did not use thyristors(scr)? it
is also act as a switch,then what is the drawback of scr as
compared to above transisters> if we use the scr,then what
is happening ? plz give reply as soon as possible bcoz i
am doing project on smps. plz frnds i want ans for
that. if anybody know the ans plz send to my e-mail
id /swathi.tadakapally@gmail.com/

Answers were Sorted based on User's Feedback



i am swathi, b.tech 4th year. In smps(switched mode power supply)we are using diodes,mosfets,igb..

Answer / nithi

SCR cannot be used due to the following reason.

1.we have to design commutation circuit for SCR.(this will
increase the complexity of the circuit)

2.cost of SCR is higher than MOSFET,TRANSISTOR & IGBT.

3.SCR is current controlled device .This will increase the
load on the triggering circuit.

4.The voltage drop & power loss in SCR is somewhat higher
than mosfet,igbt & transistor.

5.moreover,the switching frequency of the SCR is very low
(around 1khz).

so,I think it is better to use MOSFET,IGBT & TRANSISTOR as
a switching device in SMPS.OK............

Is This Answer Correct ?    19 Yes 3 No

i am swathi, b.tech 4th year. In smps(switched mode power supply)we are using diodes,mosfets,igb..

Answer / prasad,clp(power)

Hi dear this is prasad from clp (power)...we can use
thyristor(scr) but for scr we have to design firing angle
circuit separatly,we have to check whether scr is
triggering or turning on exatctly as per our requirements
or not and for high power applications it is better to
diodes,mosfet,igbts..in these we wont face firing angle
circuit design problems...bocz for the SCR firing circuit
is the heart hope so....

Is This Answer Correct ?    10 Yes 6 No

i am swathi, b.tech 4th year. In smps(switched mode power supply)we are using diodes,mosfets,igb..

Answer / g venkateswarlu

hi dear swathi,as per your question SCR act as switch but it is current controlled device and its operating frequecy is 400-500hz, voltage drop less than 2 volts,and its application are dc motor control and rectifier and inverter. where as MOSFET AND IGBT voltage control device and above nithi ans also correct

Is This Answer Correct ?    0 Yes 0 No

i am swathi, b.tech 4th year. In smps(switched mode power supply)we are using diodes,mosfets,igb..

Answer / anjun

hi swathi....its better to ask in GATE FORUM, where u will find correct ans......Anjun

Is This Answer Correct ?    0 Yes 2 No

i am swathi, b.tech 4th year. In smps(switched mode power supply)we are using diodes,mosfets,igb..

Answer / w

Yes u can use the SCR

Is This Answer Correct ?    1 Yes 8 No

Post New Answer

More Electrical Engineering Interview Questions

what happen when generator neutral supply and transformer neutral supply linked

3 Answers  


please tell me how a surge protector work on a DC 48Volt.? please describe briefly.

0 Answers  


A 6-pole, 50 Hz, 3-phase synchronous motor and on 8-pole, 50 Hz, 3-phase slip-ring induction motor are mechanically coupled and operate on the same 3-phase, 50 Hz supply. If they are left open-circuited, then the frequency of the voltage produced across any two slip rings would be

2 Answers   L&T,


can d.c.transformer exist? if yes then what its max. rating?

6 Answers  


what is the difference between Earth and neutral? and what is the difference between ground earthing and neutral earthing?

2 Answers  






why voltage rating of transformers are in multiples of 1.1?

3 Answers  


Hello Guys !! i want to rrb section engineer electrical(signal) previous model papers? any body help me?

0 Answers  


What are high pass filter and low pass filter? and What are the flowmeter ?

0 Answers  


A 3-phase IM is supplied from 50 Hz system. It runs at speed of 1440 rpm and slip equal to 4 %. Calculate number of pole pairs. A 1 B 6 C 2 D 3

0 Answers  


what is CRGO Transformers?

6 Answers   MSETCL Maharashtra State Electricity Transmission Co Ltd, TATA,


What are all the problems occured while ac generator running in leading power factor at full load condition?

1 Answers  


how to size H.T & L.T Panel ?

0 Answers   Schneider,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5084)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)