In smps(switched mode power supply)we are using
diodes,mosfets,igbts for controling of current.
And my question is why we did not use thyristors(scr)? it
is also act as a switch,then what is the drawback of scr as
compared to above transisters> if we use the scr,then what
is happening ? plz give reply as soon as possible bcoz i
am doing project on smps. plz frnds i want ans for
that. if anybody know the ans plz send to my e-mail
id /swathi.tadakapally@gmail.com/
Answer Posted / nithi
SCR cannot be used due to the following reason.
1.we have to design commutation circuit for SCR.(this will
increase the complexity of the circuit)
2.cost of SCR is higher than MOSFET,TRANSISTOR & IGBT.
3.SCR is current controlled device .This will increase the
load on the triggering circuit.
4.The voltage drop & power loss in SCR is somewhat higher
than mosfet,igbt & transistor.
5.moreover,the switching frequency of the SCR is very low
(around 1khz).
so,I think it is better to use MOSFET,IGBT & TRANSISTOR as
a switching device in SMPS.OK............
Is This Answer Correct ? | 19 Yes | 3 No |
Post New Answer View All Answers
Whether power factor should be high or low? Why?
Which material is used for the core of a transformer and why?
2. What are the parameters of EHT sub-station?
What is signal flow graph?
what are the possible reaons & remedies if resistance of NGR getting heat up
Please nybody say, weather the result of Bharat Oman is declared or not? Probable date of declare???????
Whar is the KvA rating of 33Kv substation & actual kv rating of power generaating station.
How many types of faults are there in 3 phase power system?
What are different types of control systems?
What will happen if the voltage in my house drops from 220V to any lower voltage?
what is kvarh? Please define it With calculation General motors ?
can the measured percentage error during calibration of single phase energy meter be negative?
what is meant by moulded case circuit breaker ?
What are the factor to be consider for CT selection in 132kV substation?
how i calculate the syncrones generator NGR resistance .if we have a 6mw generator line voltage of generator 11kv also line current 393.3 ampere.