what is the difference between electrical & electronics
TCS, Satyam, Infosys, GDA Technologies, Banking, MBA, Snow White, Axon Constructions, Satyam Tech,
245 2223872 Diesel Generators 900KVA connected to the bus bar for essential load as an alternative for power taken from 11/440V 3KVA Transformer supplying this bus bar. my question here is in the event of power failure on 11KV side can I feed the power to 11 KV bus by using the same transformer as reverse feed, what will be the inrush current???
3 9403railway exam in asst loco pilot old test paper
RRB, TATA, Loco Pilot, Vimal, Indian Railways, Southern Railways,
25 28663hi friend i am going too attend for hpcl in this month please help me by sending written test question papers i am in the stream of E.E.E
HPCL,
849capacitor is load free component but why ampare meter shows the current when the capacitor bank breaker close?
OPS,
4 4811capacitor is load free component but why ampare meter shows current when capacitor bank breaker close?
5 9771Post New Electrical Engineering Questions
what is ground fault in ACB?
for 4 MVA , 33K.V/6.6K.V transformer. secondary side the connected load is 3000H.P. What is the rating of capacitor bank to be insttaled.
We have 250 KW x 2 motors, which are load from 25% to 100% varying load in every minute , so how can we compansate the power factor. pl give your opinions on the above subject.
where can i get vijaya electricals limited in hyderabad interview auestions can u give me the website address plz
How do we calculate transformer oil in liter from the rating of the transformer.
what is the principle of the single phase energy meter? and,what is the advantages and disadvantages of single phase energy meter?
can i connect the two phases of scott connected transformer,if not why?
how the synchronizing is obtained at bus couplers in grid substation? (because there we cannot change the frequency in one of transmission lines like in generator synchronization)
what is the difference between switch yard to residential area.and how much required it.
temp of cast resin 1500kva tx formerwent up to 138.c but came down very fast to about 100.c within 20 mins when load was reduced from 70% to 60%
What willbe change in programming when we use 5/3 solenoid inplace of 5/2 in operating of a cylinder?
HOW TO CALCULATE CAPACITOR BANK OR HARMONIC FILTER CALCULATION
We have a distribution transformer of 750KVA/11kv/440v and an AVR (Servo Stabilizer) of 750KVA on the LT side of distribution transformer. Also we have an ACB of 1200A on the output of distribution transformer (that is on the input of AVR). We want to have an MCCB on the output of AVR. What should be the rating?
WHERE CAN I GET THE PREVIOUS QUESTION PAPERS OF Govt Polytechnic in deee 2nd year papers
(1)Can earth and be conected together (2) what is the diferent between earth & neutral