Civil Engineering (5086)
Mechanical Engineering (4453)
Electrical Engineering (16638)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379) why the generating voltage in India is 11kV or why is it be transmitted as multiples of 11
ACC, Bhel, ECI Engineering and Construction, NTPC, SBL, Senthur Power Services,
34 125258What is the difference between online ups and offline ups?
Electrical Tech, GMR, Gravity India, HCL, Indus Towers, NIT, Pyramid, Techno Electric and Engineering, UBS,
44 220607I am in India. Employer A got approval for my H1. But they have no job for me now. Company B is going to file H1 for me. They do not know about company A. Is there any way that I get approved H1 of company A transferred to Company B?
2172
what is the basic need for tech..test?
when did actually oil exploration start
what & how to check the lightning arrester
What is mean by the error LVALUE REQUIRED in C language
Why you are switching off arc protection mcb when you are taking shutdown for lv board.
diff. between tension mode & speed mode
Explain why making capacity of the circuit breaker is higher than breaking capacity?
please can any one send me BHEL ECE sample papers
why we use ac supply as 415 volts instead of 415 v why we cant apply 230 v for dc
Mention what are the physical types of fibers?
My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I - is the value of AC fault current. t - is the operating time of disconnecting device in seconds. K – is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.
How does a super charger work in a car?
What is the difference between DI pipes, Cast Iron pipes, LA Pipes, SW pipes, SWR Pipes, RCC hume pipe, RCC spun pipe ? What are their IS codes and applications ?
why ht cable end termination don't have a gland?
how to take concrete quantity for precast segment for viaduct project?