Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Why do we use stirrups in columns?

Answers were Sorted based on User's Feedback



Why do we use stirrups in columns?..

Answer / mohammed aijaz hussain

Stirrups bind and hold longitudinal bars of steel in
position. The object is to prevent the buckling or spreading
out the longitudinal reinforcement and also to prevent
concrete from splitting outwards.

Is This Answer Correct ?    165 Yes 16 No

Why do we use stirrups in columns?..

Answer / khalil

for shear

Is This Answer Correct ?    70 Yes 16 No

Why do we use stirrups in columns?..

Answer / zack yussof

to avoid the beams from buckling

Is This Answer Correct ?    37 Yes 16 No

Why do we use stirrups in columns?..

Answer / eng. wesam m. nabus

COLUMNS STIRRUPS (NOT HOOKS (KEYS)) have two purposes: 1>to fix and prevent the longitudinal (main) steel bars in columns to bulging under the vertical forces (compression force) specially in the middle of the column before reach the concrete. 2>and also intensify the quantities (diameter or by spacing) of stirrups at both ends of the column for the purpose of resisting the horizontal forces that generate horizontal shear forces on both ends of the column. SO WE CAN NOT SAY COLUMN STIRRUPS HAVE THE SAME PURPOSE OF BEAM STIRRUPS. AND ALSO THERE ARE HOOKS YOU CAN USE IN THE COLUMNS BUT ARE NOT FOR THE SAME PROPOSE OF THE STIRRUPS.

Is This Answer Correct ?    18 Yes 2 No

Why do we use stirrups in columns?..

Answer / vivekanandan.s

to tie up the bars and also to prevent from shear failure

Is This Answer Correct ?    21 Yes 7 No

Why do we use stirrups in columns?..

Answer / anand shaw

for resistance to shear failure and bending

Is This Answer Correct ?    19 Yes 8 No

Why do we use stirrups in columns?..

Answer / soumen jana

To prevent shear
stress.

Is This Answer Correct ?    13 Yes 7 No

Why do we use stirrups in columns?..

Answer / ammar bhati

Steel stirrups are installed at around the vertical main reinforcement,other than the function of shear reinforcement it helps to avoid the lateral deformation of interior concrete so that the strength of column increased.

Is This Answer Correct ?    8 Yes 2 No

Why do we use stirrups in columns?..

Answer / subbu

shear, bending

Is This Answer Correct ?    14 Yes 9 No

Why do we use stirrups in columns?..

Answer / tapan kumar samal

1.to prevent from shear failure
2.to avoid buckling of column

Is This Answer Correct ?    10 Yes 5 No

Post New Answer

More Civil Engineering Interview Questions

37.18kg/qu.cm.Compressive Strength and 10.20% Water Absorption weight,Efflorescence-nil  this result use in construction work

1 Answers  


Any strength is a stress but any stress is not strength

0 Answers  


which"s we should use for concrete ppc or opc?

9 Answers   Wipro,


what is a coupler and where do u use it ?

1 Answers   ITC Infotech,


how many kg cement & fine sand reqird in one sq meter 1:6 mortar ratio?

0 Answers   ABC, L&T,


how much deduction will be in 32 mm dia HYSD steel bar for 45 and 90 degree bend

0 Answers   CDSIPL Centrodorstroy India Pvt Ltd,


What is Pavement & carrage way?

7 Answers   NBCC,


What is factor not to be taken in consideration in mix design?

0 Answers   MMUP,


how to check and keep control on the wastage of material at site

0 Answers   Aashray Design Consultants, ABC Infra, Jain Group,


pls can some one tell me details of coloumn shuttering like at what distance the supports should be palace and no. of supports

1 Answers  


In an aggregate blending plant, water is sprayed before blending is performed. If the fine content in aggregate is as high as 25 %, will not the fines form into lumps / balls and distribution will not be uniform ? Further, the fines will stick onto the interior of pug mill and its content will be low. The mixed material is stockpiled for weeks / months before use. Will it not be better that blending is done in dry condition, and water will be added only during compaction at site. Please forward your comments and suggestions.

0 Answers  


how many bricks,cement,sand of a 40*30*6 ft bowndry wall?

6 Answers   Natco, NGO, OGDCL, SIL, Simplex,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4453)
  • Electrical Engineering Interview Questions Electrical Engineering (16638)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)