Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

What is the 415V AC Soft starter? Explain with an example?

TCS,

1 4741

Explain types soft starters?

Siemens, TCS,

7 21934

TELL ME, WHERE SHALL I GET BASIC ELECTRICAL ENGINEERING BOOKS IN INTERNET?IT SHOULD CONTAIN ALL DEFINITIONS?

TCS,

2322

Why DC current is not used in transformer?

JK Paper, TCS,

20 42523

what u meant of power plant?

5 9222

if 50hz transformer is required to be run on 50% frequency what needs to be done???????????

century,

6 11573

How Negative Phase Sequence Relay works in case of Synchronous Motor?

L&T,

4 31644

How we detect the leakage current of 11 KV H.T. motors and waht is the maximim limit?

Ambuja, Pristine,

3 9581

HI SIR, AM PREPARING FOR RRB FOR SECTION ENGINEER POST. PLZ SEND ME THE PREVIOUS QUESTION PAPERS AND HELP ME. I HAVE NO ENOUGH TIME MY EXAM DATE IS 22ND JUNE.... MY EMAIL ID IS nalla.amarnath@gmail.com

1933

Slow acting fuses are most often used for which application a) Lighting circuit b) heating circuit c) Motor D) Radar circuit

1 3861

What are the consequences in using existing step up transformer (primary 6.6kv/175A, secondary 480v/2405A) for step down transformer to have a 6.6kv output?

1 3570

what is neutral grounding? why is it required? what is neutral grounding resistor and how is its value calculated??

NTPC, ONGC,

11 65764

Why we are using Ohm's law? where it is applicable? explain.

Pyramid Saimira, TCS,

10 21217

WHAT IS BASICS TO SELECTION OF 11 kv Trasformer, send any calculation sheet for selection of transformer

NBCC,

3 10601

Does frequency change with increasing voltage i.e 220v to 11kv? explain if not?

6 11022


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

when we decide to use soft starter drive or vfd drive in mcc to operate apump?

1981


How will you utilise electrical power? You can start from the generating station.

1914


how we findout a ignater is faulty or not?

2108


Why do we mostly prefer to generate and distribute electricity in 3 phase and not in 4 phase or 5 phase?

1209


what is the practical application of full adder circuit?

1854


How work of capacitor in dc supply...???

1606


Explain the role of a car driver as one of a feedback mechanism.

1188


when qty of cable being purchased is not sufficient according to the standard,what should the inspector do to ensure its quality according to the standard?

2078


what is the maximum temperature rating of a thhn insulated conductor?

1854


please give me all the Alarm .Trip ,Safety Relays & Conditions of UPS Systems mail me on ashokbabunhce@gmail.com

1789


If we are given a 10 amp cable type and asked to calculate the number of cores used and the thickness of the cable, how do we do it?? please help...urgent!! i hope the question is clear enough!!

1830


what is static frequency converter?what is the function...of sfc...?

2241


Draw the wave shape of armature current in a generator subjected to a sudden three phase short- circuit at its terminals. Define various reactance of generator from this wave shape.

2225


how to select size of hardware for linking aluminium busbar is it depend on area of busbar or current flowing through bus bar

2021


When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<

2155