Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...



Engineering Interview Questions
Questions Answers Views Company eMail

Why air gap in rotating machines should be small?

3 8006

Why rotating machines are not allowed to run near critical speed region?

2 6731

From stability point of view,What(higher/lower) should be the value of inertia constant of rotating machines?

1 3892

How to calculate cement qty of M10, m20, m25 ? I got the formula but I lost it.

3 60223

Cement Co-eff. in block 1:6, brick1:4 work?

2 7371

how to reduce humming noise in transformer?

3 10410

There are two nos of 33Kv/11Kv 5MVA transformers conecting through HT cable from substation having metering at substation itself.One transformer used at a time another remains stand by.Further 11 nos of 11Kv/440V transformers are attached on it and each transformer is having its own Power factor correction panel.Now one 33/11Kv transformer at no load condition/Stand by condition is having power factor in leading side upto 0.21 and while when another tranformer at same situation have power factor in lagging 0.42. Now one thing is clear that transformer one is having 1.5 Km long 33kv cable due to that PF goes in leading side and another is having only 250 mtr length remains him lagging. Now i want to know that how i can maintain the Power factor at no load/ stand by position though both are behaving in seperate manner.

1 6876

what are the things to be mentioned for the question "Tell me about yourself??

CTS, Patni,

6 9408

how to calculate the density for high density concrete ? or is it same as the density of RC?

Gammon,

2502

Why oil preferred over the air as a cooling medium for high rated transformer?

1 4455

What is emperical relation.Name few of them which are used in electriacl engineering?

1 4256

In the ACB breaker capacity is 2000Amp but this each phase taken 1250 But total beldibg load is 600amp or 700amp watt is the problem

2025

difference between dol and rdol startors?

Vijai Electricals,

2 34128

what is value of Jin transformer

2154

How to check percentage of bulkage of sand in RCC?

4 24208


Un-Answered Questions { Engineering }

How much cement is require in one sqft area in a G+3 residential construction.

2188


What is the meaning of less pumping in AC

2055


do you think we shall remove un wanted soil for foundation excavation even if the thickness of the soil strata is more than 8m ?

1744


What is Anemometer used to measure?

1185


what is zone a n zone b?why the spacing of ring in zone a less.n zone b high?

2085


The resistance to the vehicle motion whose magnitude remain constant with respect to the vehicle speed is a) Resistance due to gradient b) Resistance due to the road c) Resistance due to the tyre friction d) all of the above

1575


how to select fuse rating for a 3-phase motor ???

1854


WHAT IS MEAN BY DENSITY COMPESATIVE STEAM FLOW EXPLANE?

2531


Explain what are differential gain and common-mode gain of a differential amplifier?

1296


Describe the sections included in a typical bill of quantities

2328


Is there a handy way to determine if a horizontal pipe is running full if the flow rate is known?

1121


please give me all the Alarm .Trip ,Safety Relays & Conditions of Chiller mail me on ashokbabunhce@gmail.com

1888


What is an inverter?

1135


Why a tesa lamp is glow between two phase?

2061


What is precision of a measurement?

1172