Follow Our FB Page << CircleMedia.in >> for Daily Laughter. We Post Funny, Viral, Comedy Videos, Memes, Vines...


the max. power will be transferred if ……
a) sending end vol. is high b) receiving end v is high
c)…….. d) corona loss is least

Answers were Sorted based on User's Feedback



the max. power will be transferred if …… a) sending end vol. is high b) receiving end v is..

Answer / deepakrocks4all

sending end voltage is high

Is This Answer Correct ?    3 Yes 1 No

the max. power will be transferred if …… a) sending end vol. is high b) receiving end v is..

Answer / gms

@ 1st answer-dude itts a fill in da blanks

ans-power transmitted sacross a line is given by
P=(Vs)(Vr)sin(delta)/X
Vs=sending end volt
Vr=recieving end volt
delta=rotor angle of alternator
X=inductance of line
so power transferred is high if Vs,Vr,delta are high
and inductance is low

Is This Answer Correct ?    1 Yes 0 No

Post New Answer

More Electrical Engineering Interview Questions

in DG synchronization system can i short R,Y,B- phase(DG-1) to R,Y,B Phase (DG-2), HOW IT WORK . WHAY WE NEED TO SYNCHRONIZATION.

1 Answers  


All the socket in a room become very hot, the Wall was also became very hot and the earth conductor also became live, what in your view might be the possible causes?

0 Answers  


why in the three pin plug all 3 pins are cutted ?

0 Answers  


How do we calculate the maximum amount of current in a 300 SQ.MM cable ?

0 Answers   Roto Power,


If we are given a 10 amp cable type and asked to calculate the number of cores used and the thickness of the cable, how do we do it?? please help...urgent!! i hope the question is clear enough!!

0 Answers  






How does a clampmeter measures dc current

1 Answers  


What is difference between YNyn0 and YNyn ??

0 Answers  


how to find out basic difference between ELCB,MCB AND RCCB on seeing the materials?

1 Answers   L&T,


my company total load is 1000kw, 415volt, all load are inductive load. incoming powerfactor is .8. we want to have0.95 pf connecting capacitors. so now how much rating of capacitors we have to connect? show how?

3 Answers  


If the capacitor bank is installed in switchyard say 132/22kv then on LT side say 22kv/0.433kv is it necessary to install capacitor bank for maintaining power factor. if pf is maintained on HT side then will that be maintained on LT side as well.if not then how&why??????/ please explain...........

3 Answers   MacLellan,


the question is about buchloz relay why we called it buchloz relay

7 Answers   HIL,


what types of electrical & mechanical test conducted in switchyard?

0 Answers  






Categories
  • Civil Engineering Interview Questions Civil Engineering (5076)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4445)
  • Electrical Engineering Interview Questions Electrical Engineering (16606)
  • Electronics Communications Interview Questions Electronics Communications (3915)
  • Chemical Engineering Interview Questions Chemical Engineering (1092)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (214)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (258)
  • Instrumentation Interview Questions Instrumentation (2992)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (123)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (0)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1378)