WHY HUMMING SOUND OCCURED IN HT TRANSMMISSION LINES ?
Answers were Sorted based on User's Feedback
Answer / dinesh
Blueish colour around conductor & Hissing sound is appeared
due to corono
| Is This Answer Correct ? | 29 Yes | 6 No |
Answer / koti
Plz study corona effect . then u will come to know.
ionisation of gases will happen and causes to move the
electrons randomly in all directiond and collides with
other molecules continuosly causes the humming noise.
| Is This Answer Correct ? | 17 Yes | 2 No |
Answer / nagaraju
when transmission voltage exceeds 30kv/cm breaking voltage
occurs due to this ionization will take place around the
conductor follwed by hissing noise ,color appearing ,light
glowing finally corona
| Is This Answer Correct ? | 11 Yes | 1 No |
Answer / rajesh
whenever voltage in lines exceeds breakdown
voltage(depending on weather ,fouling)the air surrounds
conductor is getting ionized with bluish colour and random
movement of electrons the collision of electron causes a
circulating current in air and produces sound
| Is This Answer Correct ? | 9 Yes | 2 No |
Answer / vikrant
corona is basically due to the ionisation of air near the
conductor, whose diameter is very small as compared to the
distance between the conductors.hence air near the
conductor ionises and ozone gas is evolved and it produces
a hissing sound. corona efect can be seen clearly during
night.
| Is This Answer Correct ? | 6 Yes | 2 No |
what is the frequency of direct current(dc)?
12 Answers Cognizant, University,
HOw can we calculate power factor at HT side.
what is power?
what is the difference between rccb and elcb?
Which capacitor is used in ceiling fans ?
what will happen if we pass a dc current through a ac bulb of 60 watt.The dc current is half ac one
what type of protection used below 132KV feeders
11 Answers APTransco, Telecommunications, wbsedcl,
What is the difference between circuit and network.
15 Answers Jadavpur University, Sail, TCS,
how can alculate the apfc panel rating?
detailed procedure how we calculate cost for pcc m10 and rcc m20 including centering and labour excluding steel/ iron
present we are having 0.8pf but I want increase it up to 0.99 so what is the formula for it and how can i calculate?
requirements for making parallel operation of Uninterrupted power supply
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)