Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


why is an oxygen sensor used in a boiler stack

Answers were Sorted based on User's Feedback



why is an oxygen sensor used in a boiler stack..

Answer / mithilesh kumar

Oxygen sensor is a vital role in boiler.we maintaim
3-5%.
In atmoshphere 21% oxygen.
So if we are feeding coal in boiler at running plant,
or hot lightup or coldlightup that time it's role is very
important.ie it's shows coal burning or not.

Is This Answer Correct ?    5 Yes 1 No

why is an oxygen sensor used in a boiler stack..

Answer / ravi kumar

since oxygen is necessary to create firing in furnace,the oxygen sensor is placed so to matain the combustion control for the fuel used

Is This Answer Correct ?    2 Yes 2 No

Post New Answer

More Instrumentation Interview Questions

When doing a liquid seal on a differential flow transmitter , most of the time the sealing liquid will be heavier then the process fluid. For wich application will the sealing liquid be lighter than the process fluid if transmitter is mounted below the process line.

0 Answers   Chevron,


how many types of sensor in instrumentation

3 Answers   SRACO,


what is the advantage of submersible level transmitter compare to ultrasonic level transmitter?

0 Answers  


pls any1 sugges me book for plc,dcs & scada..

1 Answers  


What is an antisurge control system, how it works?

3 Answers  


when the instrument tapping on pipe line is located below and transmitter is located above the tapping point for liquid service transmitter, what should we do, is there any additional drain valve is required??

2 Answers  


how to measure low temperature(<100 dec celsisus) with non condact sensor

2 Answers  


WHAT IS THE MAIN WORKING OF BOILER.

3 Answers  


what is upstream and downstream in liquid flow?

6 Answers   Thermax,


what can of fault ofently come in vibration mesurement?

0 Answers  


GWR radar transmitter working principle?

2 Answers   Tata Steel Limited,


what is the difference between AUTOMATION AND INSTRUMENTATION?

7 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)