what is the formula to calculate isolated footing
Answers were Sorted based on User's Feedback
Answer / rethina kumar
isolated sloped footing
flat portion : L X B X D = VOLUME1
SLOP PORTION : A1+A2+ (A1 X A2 ROOT)X H/3 = VOLUME2
VOLUME = V1+V2
| Is This Answer Correct ? | 254 Yes | 34 No |
Answer / chelladurai
V=LxBxd+((h/6x(A1+A2+4Am))
where
d= base height
h=total height - base height
A1= bottom area
A2=top area
Am= mean of top and bottom area
| Is This Answer Correct ? | 59 Yes | 16 No |
Answer / sanjay pati
1ST_ FORNULA :L*B*H +A1+A2+A1*A2 RA ROOT OVER
*H/3
| Is This Answer Correct ? | 29 Yes | 11 No |
Answer / vignesh
d+(D-d)/2*length*bradth
d=clear depth
D=overall depth
| Is This Answer Correct ? | 29 Yes | 17 No |
Answer / mayank bansal
H(A1+A2)/2
It can also be used.
It mainly depends up on client that which formula to be used in the starting of the projects.
| Is This Answer Correct ? | 18 Yes | 8 No |
Answer / pawan kumar
V=LxBxd+((h/6x(A1+A2+4Am))
where
d= base height
h=total height - base height
A1= bottom area
A2=top area
Am= mean of area at mid section
| Is This Answer Correct ? | 8 Yes | 5 No |
Answer / mohammad razauddin
Flat portion : L X B X D = VOLUME1
ISOLATED PORTION : A1+A2+ (A1 X A2 ROOT)X H/3 = VOLUME2
VOLUME = V1+V2
where
A1= bottom area
A2=top area
| Is This Answer Correct ? | 4 Yes | 2 No |
Which one is the main bar in a square slab (2m x 2m)
how is shear resisted in a structure?
WHAT HAPPEN WHEN USING OF LARGEST POSSIBLE MAXIMUM SIZE AGGREGATE RATHER THAN SMALLER AGGREGATE IN RCC ?
Explain the benefits of using standard terminology in the measurement process?(Tendering and estimation)
How can we convert weight batch to volume batch for m30 mix
50m3 concrete volume how much cement sand aggregate details radio m20grade
5 Answers L&T, Mars Planning Engineering Services, Relcon Infraprojects,
why steel tanks are provided (a) for water pressure (b) for wind pressure (c) for earthquake pressure
How to calculate per inch area in a circle?(Dia is 2.17m)
how much shuttering oil required for 100 sqm shuttering?
How to calculate Brick for 9"wall for100sqft
What is the calculation for finding cement and sand for 10' * 12' area ratio 1:6 thickness 12 mm
what is the ratio of concrete to steel? what's its value??
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)