shuttering consumption per square feet in multi storeyed
building?

Answers were Sorted based on User's Feedback



shuttering consumption per square feet in multi storeyed building?..

Answer / mahi

7 Sq.m / Cum of concrete..

Is This Answer Correct ?    18 Yes 1 No

shuttering consumption per square feet in multi storeyed building?..

Answer / mahi

7 sq.m / cum of conrete

Is This Answer Correct ?    16 Yes 3 No

shuttering consumption per square feet in multi storeyed building?..

Answer / shiva

Ax0.125m=1cum
A=8Sqm

Is This Answer Correct ?    2 Yes 0 No

shuttering consumption per square feet in multi storeyed building?..

Answer / mahesh mishra

Its not standardized but depends upon the architectural designs.

Is This Answer Correct ?    1 Yes 1 No

shuttering consumption per square feet in multi storeyed building?..

Answer / divusp

6 times of concrete qty 1 cum= 6 sqm,
2.4 times of build up area 1000sqft=2400sqft shuttering.

Is This Answer Correct ?    3 Yes 3 No

shuttering consumption per square feet in multi storeyed building?..

Answer / ncmaan

ITS DEPENDS ON NUMBER OF STOREY

Is This Answer Correct ?    1 Yes 3 No

Post New Answer

More Civil Engineering Interview Questions

for plaster what is the suitable sand.

3 Answers  


Design a reinforced concrete combined footing (rectangular) for two columns located 3.60 metres apart. The overall sizes of the columns are 40cm x 40cm and 69cm x 60cm and the loads on them are 1000 kn and 1500 kn respectively. The space available for the width of the footing is restricted to 180cm. The S.B.C. of the soil is 280 kn/mm2 use M15 concrete.

1 Answers  


Coarse aggregate & fine aggregates are called inert material when used in RCC work because------

5 Answers  


what is the code provision for acceptance of fineness modulus range for fine aggregates in design mix

2 Answers  


What is NP in "NP BIB Tap"?

2 Answers   APTransco,


by which IS Code bend correction is two times of the dia meter of steel is taken

3 Answers  


how to distinguish TMT n Tor steel?

2 Answers  


What is cold joint, what will happen due to cold joint?

1 Answers  


what"s the ratio for M30,M35,M40,M80 grade concrete?

0 Answers  


what is c4x light weight cement blocks

1 Answers  


why we use for testing of compression strength concrete the size of specimen 150x150x150. why we are not using another dimension like 100x150x100 uneven dimension.

1 Answers   Guru Nanak,


how lap length is increased with increase of Grade of steel?

3 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4453)
  • Electrical Engineering Interview Questions Electrical Engineering (16638)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)