Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


When we calculate Impurity against impurity std.solution
and when we calculate impurity against diluted standard with
applying RRF?

Answers were Sorted based on User's Feedback



When we calculate Impurity against impurity std.solution and when we calculate impurity against di..

Answer / mukesh patel

impurity can be calculated against impurity when impurity
availability is sufficient.and easily available for routine
analysis and there is huge difference in RF or RRF with
main analylte.impurity can be calculated against diluted
standard with applying RRF when peak get saturated in
sample solution.

Is This Answer Correct ?    14 Yes 0 No

When we calculate Impurity against impurity std.solution and when we calculate impurity against di..

Answer / sp goswami

We need calc of imp RRF against impurity std when our
impurity responses are improper with st. phase of that
column and also if imp. is available in sufficient quantity
for diluted std we can cal for quantified results and if
impurity is less in amount and response is also less ,so to
get a perfect calculated % impurity we quantify it with
help of diluted std.
Regards

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

why should we calibrate pH meter with 4,9.2 and 7.4 buffers particularly?

5 Answers   Celon Labs,


IF HPLC CALIBRATION FAILED THEN WHAT YOU DO

6 Answers  


What is shaking level in GC?

0 Answers  


what is the difference betwen the analytical column & peparative column?

4 Answers  


why kf factor coming 0.5

5 Answers   Alkem Labs,


Please give idea about method development for cleaning method and how maco level establish

0 Answers  


How can we calculates the solubility of the drug in different medias by injecting in to hplc????(solubility studies)

2 Answers   Super Pharmaceuticals,


Which water can use Hplc analysis

9 Answers   BioGenomics, Dr Reddys, Reddy Labs,


In HPLC (Waters) software Empower1,2 &3 what is the updation for each version

0 Answers   APL,


what is dissolution

6 Answers   DRL,


What is cleaning validation of rinse and swabe and its limit with caculation formula.

5 Answers  


If mass balance is not passing in forced degradation in method validation that method is suitable or not?

1 Answers   Aurobindo, Dr Reddys, Reddy Labs, Wockhardt,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)