how much binding wire is required for one tone steel
Answers were Sorted based on User's Feedback
Answer / durai mathan
approximately 10 kg. but due to the size of spacing it"s
varying .
Is This Answer Correct ? | 72 Yes | 15 No |
Answer / mohammed mohiddin
The question itself is not a relevant one. Binding wire
quantity varies for different kind of structural members
depending upon the design at different region of the world.
We, at UAE 've a thumb rule to estimate for this to
consider as the 2% of total quantity of steel for the
perticular project.And it worked out approximately correct
for the almost of all projects in my carrier.
Is This Answer Correct ? | 33 Yes | 6 No |
Answer / santosh singh
about 9 to 13 kg per ton as per cpwd specification
Is This Answer Correct ? | 26 Yes | 8 No |
Answer / asif shaikh
Approximately 10 To 13 Kg As it depents upon the Designof
Steel Reinforcement & Diameter of Bar To be Binded.
Is This Answer Correct ? | 21 Yes | 10 No |
Answer / muthuraj s
Approximately 7kg/MT in my site Gammon India Ltd.... We
have already calcuted and checked..
Is This Answer Correct ? | 17 Yes | 6 No |
Answer / ashish chordiya
The binding wire quantity depends design n use of wire actual site
Is This Answer Correct ? | 6 Yes | 0 No |
Answer / kapil jain
approximate 7 to 10 kg per ton binding wire required. it is depend upon the Design of
Steel Reinforcement & Diameter of Bar To be Binding.
Is This Answer Correct ? | 4 Yes | 1 No |
Answer / chandan singh bhaisora
9 - 10 kg or 2% of total consumed steel
Is This Answer Correct ? | 5 Yes | 3 No |
Answer / sanjay kumar pati
6 to 8 kg per ton ,but as per dia &speceing
Is This Answer Correct ? | 3 Yes | 1 No |
How many cement mortor dry quantity required for 1m3 ?(1:4)
How much concreat we make by 1 bag cement? (ratio- 1:1.5:3 or 1:2:4)
2 Answers Castles Consulting Engineers, KCP, Opaque Infrastructure,
For 100 cu.m of solid block masonry in CM 1:6, 8" thick. Calculate no of blocks required...? Actually I got it as 1250 no's.. But in my material it is 1100 no's.. U guys plszz check & tell me the answer......
What is used for 1cubicmeter steel ? 1meter length square pipe how many weight ?
what discoveries did you have in relation to your course?
how many types of admixters are used for C.C. Road works
1 Answers CADS Software, IVRCL, PSK,
why red bricks & cinders used in toilet sunken filling. if coarse aggreate used wat the probelem
how to tie 10 legged stirrups
What is meant by Characteristic Strength of concrete/concretemix and how is it related to the 28 day cube strength. Are these defined in either or both B ritish Standards or Eurocodes?
how much steel is required foe following components.. footing- plinth beam- column- beam- slab-
what is th consuption of cement , sand in plastering for 15mm thick cm1:4,1:3
which grade of concrete according to Indian Standard 800:2007 has highest strength?