Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


What are the chemicals are required for cooling tower
passivation?

Please mail me in my Email id:-nsput2000@gmail.com

Answers were Sorted based on User's Feedback



What are the chemicals are required for cooling tower passivation? Please mail me in my Email i..

Answer / atul $onawane

while passivation oxygen is rwemoved using sulfite to avoid
further corrosion of cooling tower parts and then chloride
cycle dealkylation process (using ion exchange
process)carbonate and bicarbonates are removed. ion exchange
process treates pretreated water.(i.e softened water using
chemical such as zeolite.)

Is This Answer Correct ?    1 Yes 0 No

What are the chemicals are required for cooling tower passivation? Please mail me in my Email i..

Answer / vinayak

WATER SOFTNER

Is This Answer Correct ?    0 Yes 0 No

What are the chemicals are required for cooling tower passivation? Please mail me in my Email i..

Answer / sundar

simple word minimize the chemical reaction in cooling tower

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Chemical Engineering Interview Questions

ENGINEERING DRAWING - EXAMPLE 18.1 : For a Vernier scale of representative fraction (RF) = 1 / 25, calculate the length of the scale for the reading up to 4 metres.

1 Answers  


Question 47 - In a cylinder with a hollow, let a is outside radius and b is the inside radius. In a steady state temperature distribution with no heat generation, the differential equation is (d / dr) (r dT / dr) = 0 where r is for radius and T is for temperature. (a) Integrate the heat equation above into T(r) in term of r. (b) At r = a, T = c; at r = b, T = d. Find the heat equation of T(r) in term of r, a, b, c, d.

1 Answers  


MICROBIOLOGICAL ENGINEERING - QUESTION 28.1 : In the calculation of the growth of bacteria, colony forming unit (CFU) in serial dilution is used. In a laboratory, viable count assay is used to estimate CFU. Formula applied is CFU / mL = (number of colonies x dilution) / (amount plated, in unit mL). Acceptable plate count is either between 20 and 200 or between 30 and 300 according to 2 different references. A wastewater sample of 200 ml is added to and mixed with 1.8 L of sterile water. Another 200 ml of the mixture is added to and mixed with 1.8 L of sterile water. (a) Calculate the dilution of first mixture and the dilution of the second mixture. (b) 100 microlitres of wastewater samples from the first mixture and the second mixture are placed separately on 2 different alga plates. The first plate has 250 colonies and the second plate has 23 colonies. Calculate the average CFU / mL.

1 Answers  


Can condensate control in a reboiler cause water hammer problems?

0 Answers  


POLYMER ENGINEERING - QUESTION 24.1 : The molecular weights M in kg / mol of 3 different monomers a, b and c in a polymer are Ma = 14, Mb = 16 and Mc = 18. The fraction of polymer chain X of 3 different monomers a, b and c in a polymer are Xa = 0.5, Xb = 0.3 and Xc = 0.2. (i) Calculate number average molecular weight by using the formula Ma Xa + Mb Xb + Mc Xc. (ii) Calculate weight average molecular weight by using the formula (Ma Xa Ma + Mb Xb Mb + Mc Xc Mc) / (Ma Xa + Mb Xb + Mc Xc). (iii) Calculate the polydispersity by using the answer in (ii) divided by answer in (i). (iv) If the molecular weight of repeat unit is 12, calculate the degree of polymerization by using the formula (Ma Xa + Mb Xb + Mc Xc) / (molecular weight of repeat unit).

1 Answers  


Heat transfer: In a triple effect evaporator, the heat transfer for an evaporator is calculated as q = UA (TI - TF) where TI is the initial temperature, TF is the final temperature; U and A are constants. Given that heat transfer for the first evaporator : q(1) = UA (TI - TB); second evaporator : q(2) = UA (TB - TC); third evaporator : q(3) = UA (TC - TF) where q(x) is the heat transfer function, TB is the temperature of second inlet and TC is the temperature of third inlet, prove that the overall heat transfer Q = q(1) q(2) q(3) = UA (TI - TF).

1 Answers  


I have Completed my B.Tech in Chemical Engineering from NIT Raipur, I want to prepare for HPCL Please Suggest me some books for Aptitude, Technical Questions & Please send me Previous Year Question Papers.

3 Answers   HPCL,


Question 89 - A hemocytometer is a device that is used for counting cells. In an engineering experiment, 100 microlitres of cell suspension is diluted with 50 microlitres of Trypan blue dye. Only death cells appear blue in color when stained with the dye. There are 57 cells detected in a hemocytometer, where 5.3 % of them appear blue when the chamber of the meter is placed under a microscope. Each square of a chamber can contain 0.0001 mL of liquid. (a) Calculate the number of viable cells. (b) The cells ocupied 5 squares. Calculate the average number of viable cells / square. (c) Calculate the dilution factor of the cell suspension by using the formula : Dilution = final volume / initial volume. (d) Calculate the concentration of viable cells / mL by using the formula : Concentration = (Average number of viable cells / square) x dilution x (square / volume).

1 Answers  


repected sir i have given gate exam today.......... if i ll get the better rank in that ....what is the next process .....shall i give another one test......or wat....i dint get properlly..... plz help me or mail me on Nish_gasti@yahoo.co.in

0 Answers   IOCL,


we have 2 O2/Comb Analyzers Servomex Model 2700 in service for one of the furnaces in our chemical plant. It is giving High Temperature Alarm. Checked Temperature and found it to be 800 Deg C whereas Set Point is 700 Deg c. It is strange why is temperature not at SP. Also response is 23 % with 21 % Inst Air and with N2 reading is not coming down. please clarrify this issuses very urgent

1 Answers  


A cylinder having water is being evacuated with constant rate. what is the relation between pressure which is existing in cylinder with time? (P and t relation)

2 Answers  


Explain the significance of the angle of repose holds in the chemical industry?

0 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)