HOw to derive reynolds equation?
Answer / shirish
reynold's number= inertial force/viscous force
= DV/u/p
=DVp/u
where D=diameter of pipe
V= velocity of water
p=density of water
u=viscosity
reynolds number derive by keeping vertical glass tube. The
tank filled with ink add in glass tube throught nozzle.
calculate flow rate.
if q<1000 laminar flow
1000<q<4000 transition region
q> 4000 turbulent.
Is This Answer Correct ? | 4 Yes | 3 No |
What is g and gc in a bernoulli's theorem?
Question 32 – Let 1 ^ 1 = 1, 2 ^ 2 = 4, 3 ^ 3 = 27. By using the Excel computer programming – either by Solver or Goal Seek, find the value of v for the Van der Waals equation (P – a / v ^2) (v - b) = RT where a = 18.82, b = 0.1193, P = 2, R = 0.082, T = 5000 for benzene. Describe briefly how to use Solver and Goal Seek in Excel program of computer to find the solution quickly.
Dear sir/madam I am in final year BE chemical engineering.Which companies i can apply .Please guide me.It is very helpful for me
what three specific job positions do u target from the company.
2 Answers Amec Foster Wheeler, Chevron, Exxon Mobil, Petrochemicals, TCS, Texaco,
Explain the method of determining maximum differential pressure during hydro testing of shell and tube heat exchangers?
How can you separate hydrogen peroxide into hydrogen and oxygen?
how can I find out a sulfuric acid recovery plant disigner?
MY generator water cooler inlet line height - 11 mtr inlet water line height - 7 mtr water come into the line from overhead tank, O/H tank height - 20 mtr the first tapping in the inlet line is 2" line which down to 4 mtr level plateform., second tapping in inlet water line goes to a pump 6" line installed at 4 mtr level plateform, pump capacity 200m3/hr, head- 30 mtr, hp-40. the outlet of pump of 6" water line connected to a header of 6 mtr long of 6" line, on this header the six tapping are connected, 4 nos. 3" line goes to 11 mtr height water cooler the pressure of the line is 0.15 to 0.25 kg/cm2, 2" and 4" pipe line connected to a cooler at 4 mtrlevel plateform. my question is, at 11 mtr height level the quantity of water and flow is not sufficient for my cooler, the temp. of cooler is rises much more. you are requested to suggest the modification of pipe line/ pump for take more water flow and pressure (desired pressure is 1 kg/cm2)
is the QURAN GOD'S words?
Explain what particle sizes are electrostatic precipitators used to remove?
Can anybody suggest the Methods/Procedures for estimation of oxygen, hydrogen, methane, carbon dioxide, CO, etc. in binary or complex gas mixtures?
Question 49 - According to rules of thumb in chemical process design, consider the use of an expander for reducing the pressure of a gas when more than 20 horsepowers can be recovered. The theoretical adiabatic horsepower (THp) for expanding a gas could be estimated from the equation : THp = Q [ Ti / (8130a) ] [ 1 - (Po / Pi) ^ a ] where 3 ^ 3 is 3 power 3 or 27, Q is volumetric flowrate in standard cubic feet per minute, Ti is inlet temperature in degree Rankine, a = (k - 1) / k where k = Cp / Cv, Po and Pi are reference and systemic pressures respectively. (a) Assume Cp / Cv = 1.4, Po = 14.7 psia, (temperature in degree Rankine) = [ (temperature in degree Celsius) + 273.15 ] (9 / 5), nitrogen gas at Pi = 90 psia and 25 degree Celsius flowing at Q = 230 standard cubic feet per minute is to be vented to the atmosphere. According to rules of thumb, should an expander or a valve be used? (b) Find the outlet temperature To by using the equation To = Ti (Po / Pi) ^ a.