What are all the possibilities discharge will be low in the
pumps?
Answers were Sorted based on User's Feedback
Answer / prof. prafulla hatte
1. Internal Leakages in pumps.
2. Lesser speed of a motor due to electrical power supply
problems.
3. High load on pumps.
4. Chocked output filter.
5. Chocked input filter.
6. External leakages from the pump.
7. Change in viscosity of the fluid.
| Is This Answer Correct ? | 39 Yes | 3 No |
Answer / sebastian paul
1.In sufficient available npsh
2.Pump is not primed properly
3.Air or vapour, pockets in the liquid on the suction side.
4.Low voltage resulting in lower rpm
5.Required head being higher then the developed head
6.Impeller vanes clogged up
7.Worn out wearings
8.Viscocity of the liquid not as per specification
| Is This Answer Correct ? | 12 Yes | 1 No |
Answer / jagadesh
1.In sufficient available npsh
2.Pump is not primed properly
3.Air or vapour, pockets in the liquid on the suction side.
4.Low voltage resulting in lower rpm
5.Required head being higher then the developed head
6.Impeller vanes clogged up
7. Chocked output filter.
8. Chocked input filter.
9. External leakages from the pump.
| Is This Answer Correct ? | 6 Yes | 0 No |
Answer / ravindra
also design defects matter in discharge.if there is bend in
the pipe then losses will be more that affect the
discharge.
| Is This Answer Correct ? | 7 Yes | 3 No |
Answer / yesm
also checked the direction of rotation of pump due to
wrong electrial connection.
| Is This Answer Correct ? | 3 Yes | 2 No |
Answer / madhappan kaliyannan
1.NPSH Issue
2.Pump priming not properly
3.Cavitation issues
4.pump direction
5.Required head being higher then the developed head
6.wearing worn out
7.Defend the fluid viscosity.
9.Suction line may be having hole/leakage.
10. Suction line strainer may be got choke
11. Suction line may be volume reduced ( Because of process fluid, like a scale formation )
12. may be more leakages from pump like gland/discharge line/recirculationline
| Is This Answer Correct ? | 0 Yes | 0 No |
Answer / n.bargavi
As the resistance to flow in the internal impeller inlet,
discharge ceases. that s due to high pressure. when the
pressure head is same at two points discharge will be maximum
which means no work is required but as the head increases,
the discharge reduces which means at maximum head, discharge
is zero given by main characteristic curve.
| Is This Answer Correct ? | 0 Yes | 1 No |
Why entropy change for a reversible adiabatic process is zero ?
DENSITY OF AIR AT 300 DEGREE CENTRIGRADE
Sir/Mam, I have applied for RRB chennai for the section engineer - mechanical posting. If any one is having the old written exam question papers please send it to my mail id : spramu@gmail.com Thanks in advance, Ramanathan...
Explain working of francis turbine?
Give the purpose of nozzle in impulse turbine?
2 Answers ABC Inc, RRB, Siemens,
Difference between isometric & trimetric view
Name of the tables which is going to join two tables in querry ?
pulley forms which pair?
3 Answers BEL, Gujarat Guardian,
Causes of F.O. Purifier abnormal flow?
describe a type when u anticipated potential problems and developed preventive measure
How to calculate perimeter or area of 'Y' piece duct fittings ?
How to protect the pipe line from crrossion.?
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)