Basic philosophy of applying 3P tripping for uptill 132KV switchyards & for 132KV & above 1P/3P tripping is used.
L&T,
1 3634Is it necessary to seperate the DG earth grid with Electricity Board earth grid for protecting the DG set. if yes why?
BARC,
2 3864Isi standard of lux level required / to be maitained in different working place general & in textaile industry.
1 6377Post New Electrical Engineering Questions
Is there a diode made that works with AC 120 volt 20 amp? If so can it completely stop all current flow in 1 direction at all times?
Hi everyone, I'm Lachuu, recently joined automation company as PLC Engineer. I have certain basic question, I request all big gurus and seniors to answer these question. Because this will be very helpful to me as well starters like me. How to design a control circuit (ex: pick & place - my current project) Yamaha robot PxYx series controller RCX222, using 6 cylinder double acting, plc keyence kv p16r 2 expansion unit for input and output each. How to select panel terminal mcb elcb powersupply. My main concern in some projects how to select dc power supply, mcb rcb(I came across dif bt b c d curves, but stil confusing, pls help me :-(. I would really appreciate all who are going respond to this question.
we need a ntpc previous papers
RATING OF LIGHTENING ARRESTER FOR 11 KV LINE IS 9 KV is ok ,but haw to calculate the KA rating?
Dear all, how we select the cable size according to current with or without including different correction factor , is there any direct method for sizing of cable...
1- What is the Polarization Index number be good for 15KV 3c#500MCM electrical cable? 2- Can I use the IEEE Std 43-2000 to perfom the PI test? Thanks
Starting Time of LT & HT Motor
what is the use of vcb & isolator in substation?
What type of DC motor would you see for a lift?
Is there any specialised book to refer about fault level calculation both in MV and LV side??
Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.
Why the arms of delta in a delta-wye power transmission system are kept constant??
What tests should i carry over on a newly rewinded DC Generator with voltage rating of 38 volts and current rating of 350 amps, to certify that the machine is OK?
Explain about technical and non technical losses in distribution system?
What kind of Neutral CT can be placed in 11/0.433KV transformer to be used and what are its specification?