Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...



Engineering Interview Questions
Questions Answers Views Company eMail

what is the difference between DELTA-V & FOUNDATION FIELD BUS

4 11886

what is the name of transformer oil.

15 22027

In Transmission System if the potential difference at the two end of line are same then is the transmission of power will continue ? if yes then how.

IOCL,

1 2321

How to calculate the rating of ELCB OR RCCB for an equipment?

2 23830

WHAT WILL HAPPEN IF WE START A MOTOR WITH STAR & IT IS RUNNING WITH STAR CONNECTION INSTEAD OF DELTA

3 7474

What is the difference between efficiency and effectiveness of an machine,man,etc., proof with example?

1 3309

Why you prefered plastics in the optical fibre development than other material?

1883

What will be the excat cable specification in Sq MM...please find the details below.... Induction Motor HP:55 Amps:70(starting Amps),45(Running Amps). Volts:415

1 5957

why 8052 is preferred instead of ARM processors for soe applications

2151

what is the maximum current rating in india for home?

3 15803

How we calculate the current carriying capacity of the different sizes of Aluminium busbar ?

ABB, Raj Process Equipments, Visa Steel,

3 13584

Hi buddies! my name is sachin and i am working as a electrical and instrumentation engineer in a paper plant. right now i am facing a problem and if someone could help me it will be an immense pleasure to me. i am using AC 800M to synchronise DCS500 drives on paper machine and rewinder.communication is on PROFIBUS and we are using NPBA-01 module to link profibus to DC drives.But these days two of these drives are showing a error named FIELDBUS COMM.TIMED OUT and the drives get tripped.I have changed the NPBA module and PROFIBUS cable.So if anyone can do please help me out with this problem.I'll be highly grateful.

2159

Concrete Mix designs for M15,M20,M25,M30 and M35

Arelgee Consultants, ATCO, Fusion, Gammon, Power Cable, Raushan Engineers, Simplex,

23 237891

Cost control in civil construction as well as Quality control

Reliance,

11 26654

if the supply voltage increased by N times, the x-section of conductor will be.........

APGenco, Electrical Tech, Ericsson, IES, Thirumalai Chemicals,

2 6352


Un-Answered Questions { Engineering }

Why there are some equipment(i.e:TV) that using 2-pin plug instead of three? What happen if there is current leakage? Are we going to get electric shock??

2137


Please describe tar, asphalt and bitumine

1625


Define ansi?

1


What are merits & De-merits of State-Space Method? What is series programming, parallel programming, general programming & direct programming ? And, difference between these programmings Techniques ?

2377


Can we Co-ordinate relay in Load Break switch?

1924


when the generator running trip by earth current even though engine all so shut down the problem showing gcs waring and emergency trip there after starting always gcs locked out what is the problem [this is cummins qsk 23 electronic controle module governer

1823


Explain what is a latch?

1041


My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I -    is the value of AC fault current. t -    is the operating time of disconnecting device in seconds. K –  is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.

1835


What is brand?

1


What is angle and amplitude modulation?

993


Which parameter remains constant in isochoric process ?

1061


1) What are your personal strength? 2) What are your personal areas of improvement? 3) What are your expectations from from a particular job? 4) what are your carrier objectives?

2480


Give four examples for footwear used by Romans.

5


how tto ingress mw in turbine explain.procedure ?

2240


What happened if the exhaust valve is leaking?

1815