Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


if power plant is running at normal condition. at that time
accidentally turning gear motor or bearing lift oil pump
came into service menas what happen to the system?

Answers were Sorted based on User's Feedback



if power plant is running at normal condition. at that time accidentally turning gear motor or bea..

Answer / d n tiwari

if accidentally turning gear motor or bearing lift oil pump
came into service then nothing will happan to the system.
plant will be continue smoothaly only desk operator will
identify this and he should close the turning gear motor
and must check the logic again.

Is This Answer Correct ?    11 Yes 1 No

if power plant is running at normal condition. at that time accidentally turning gear motor or bea..

Answer / devanesan

Nothing will happen. at the time of load condition also the
turning gear will be in the ON condition. it is the logic.
at this condition if the JOP gets start also nothing will
happen. only posibility is the shaft vibration may
increase. one more thing is the JOP supply is in the bottom
of the bearing. the minimum oil film also near to that
area. it may breaks the oil film and cause for bearing
failure. it will happen in the worst case.

Is This Answer Correct ?    2 Yes 0 No

if power plant is running at normal condition. at that time accidentally turning gear motor or bea..

Answer / baskaran.r

the turning gear motor and drive provided to keep the rotor
in continuous rotation for fear of sagging shaft. only when
it is stopped the main drive can be started. there will be
interlocks provided and the comdition will never occur

Is This Answer Correct ?    2 Yes 1 No

if power plant is running at normal condition. at that time accidentally turning gear motor or bea..

Answer / anand swami

this condition arises when turbine trips turning gear start
when speed of motor falls below a certain speed say 800
and jacking oil oump starts to lift the shaft as due to
reduced speed film lubrication is not proper

Is This Answer Correct ?    1 Yes 1 No

if power plant is running at normal condition. at that time accidentally turning gear motor or bea..

Answer / sourav

Nothing will hapen. it may because of loose connection of
speed sensor at turbine front bearing. Turning Motor to be
stopped from CCR & connection to be tightened by C&I

Is This Answer Correct ?    1 Yes 1 No

if power plant is running at normal condition. at that time accidentally turning gear motor or bea..

Answer / umesh

Process steam suppy may get cut off.

Is This Answer Correct ?    1 Yes 8 No

Post New Answer

More Mechanical Engineering Interview Questions

solar cooker based on the principle

0 Answers  


what is differences between boiler bed temperature & furnace temperature.

2 Answers  


what do you know about the company?

1 Answers   Concentrix, Essar, Expedia, Honeywell, Huawei, Zomato,


What is the Difference between Cotter Joint

11 Answers   L&T, MAHINDRA,


i want technical interview qestion?

1 Answers   Keane India Ltd, Sonamoti,


how much people working in railways?

3 Answers   RRB,


What is called governor in gas turbines?

2 Answers   GE,


What is differance between qc & Qa? in mechanical field.

13 Answers  


What are the loads considered when designing the Nut and Bolts?

12 Answers  


Sir can u send me few interview questions and answers based on Deputy Superintendent(materials) of APSRTC. I have selected in written.reply to bhanudammoju@gmail.com thank u.

0 Answers  


why do we appoint u if we have software for same work?

3 Answers  


WHAT SHOUL BE THE RAKE ANGLE WHEN SS IS TO BE MACHINED

3 Answers   Engineers India, Engineers India Limited,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)