Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Is there any interfacing sofware to build communication
between a PC and ER300P model L&T make trivector meter via
RS485 port which is available in the meter and is there any
data acquisition card available to store the acquired data
from the meter into the system

Answers were Sorted based on User's Feedback



Is there any interfacing sofware to build communication between a PC and ER300P model L&T make..

Answer / murali

Try to get the MODBUS communication details,address &
parameters which are all can able to read from the ER300P
meter from your supplier or direct from L&T.
With those inputs we can do anything

Is This Answer Correct ?    9 Yes 0 No

Is there any interfacing sofware to build communication between a PC and ER300P model L&T make..

Answer / pearl george

there are so many softwares available on the net such as modscan, simplymodbus by which u can communicate. rs485 port uses the modbus rtu mode of communication in L&T er300p.with these softwares u can get the values like voltages, current, pf, frequency etc that are stored in the holding register of the meter. to communicate with the energy meter u hav to prepare a query with the required function code.
more details required, pls feel free to ask me

Is This Answer Correct ?    10 Yes 1 No

Is there any interfacing sofware to build communication between a PC and ER300P model L&T make..

Answer / pearl george

hey anis..
i wud b happy to help you.. but i jus remembered dat power consumption s nt available at d holdinding regisers of the meter. in my projct, i had to only acquire d pawer which i calculatd from the V, I n power factor dat will be updated in d register n d query i talked abt is used to write to dose registers.. so.. i dunno if my query wud help you..
y dnt u access d data to d pc n dn develop a software werin u can do d calculations recquired? i can try helping if dats d case.. coz v used vb.net to develop a software wer v tuk dese voltage n all n den calculated der..

Is This Answer Correct ?    2 Yes 0 No

Is there any interfacing sofware to build communication between a PC and ER300P model L&T make..

Answer / anbh

Hey I have more questions on ER300P. Can I have ur mail id
plz. Thanks. ANBH

Is This Answer Correct ?    0 Yes 0 No

Is there any interfacing sofware to build communication between a PC and ER300P model L&T make..

Answer / pearl

wat is dat u wanna knw? i comleted dat projct.. if u want ny help, mail me..

Is This Answer Correct ?    0 Yes 0 No

Is there any interfacing sofware to build communication between a PC and ER300P model L&T make..

Answer / ab

I'm using this meter to study the power utilization for
several load settings in a complex theromchemical
plant.....At the begning of every measurment I want to
round off the start point of the power consumption reading
to 4 digits (ex:xxxx0000)....so that I can apply my algo on
the readings which I get at the end of my measurement.

Does any one of you know how to do it?

Is This Answer Correct ?    1 Yes 1 No

Is there any interfacing sofware to build communication between a PC and ER300P model L&T make..

Answer / pearl george

u can write in the meter using write code using modbus. jus chek the location of the power using modscan or sum silmple software n then u can write in dat location with a loop or sumtng at ur will..

Is This Answer Correct ?    0 Yes 0 No

Is there any interfacing sofware to build communication between a PC and ER300P model L&T make..

Answer / anbh

Thank you very much George.
As I know from ER300P manual....we have a programing
password with which I can change some settings of the meter
like CT\PT ratio and RTC etc...So can I use the same
programing password to write to the location of current
power consumption?

Thank you again.

With best regards,
Anis

Is This Answer Correct ?    0 Yes 0 No

Is there any interfacing sofware to build communication between a PC and ER300P model L&T make..

Answer / anbh

Hello George,

It's again me(Anis)....
In ur 1st reply you wrote..."to communicate with the energy
meter u hav to prepare a query with the required function
code"....Can you plz share the query you worte for your
project and also plz let me know where can I find the
function code to write to the address of total power
consumption.

Regards,
Anis.

Is This Answer Correct ?    0 Yes 0 No

Is there any interfacing sofware to build communication between a PC and ER300P model L&T make..

Answer / siva kumar

Hi george, i am siva, i have L&T Trivector Meter ER300p, Can
u guide me how to take data from the meter

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Instrumentation Interview Questions

SIR MAY I KNOW IF RADAR TYPE LEVEL TRANSMITTER SHOWING IN THE FIELD 0 % LEVEL AND IN DCS SHOWING 100% THEN WHAT IS THE CAUSE I CLEAN THE CHAMBER & TAKEN ONLINE BUT ONLY ONCE ITS BECOME ZERO IN DCS BUT AGAIN 100% SHOWING IN DCS,THEN I REMOVE THE POWER SUPLLY AND CONNECT IT AGAIN .IS IT OK BUT STILL IN THE DCS ITS 100% AND ON THE DISPLAY ITS INITILAZIATION PLEASE HELP ME READRING THIS?

4 Answers  


what is function of DCS , and how is it work , explain with difination

1 Answers   Bapco Bahrain Petroleum Company,


what is maximum temprature in instrumentation

1 Answers   Sabic,


what is the meaning of wet leg & where is it used?

1 Answers  


wt kind of business we can do by usig PLC?

2 Answers   Dabur,


Emergency Shutdown Systems/ Plant Shutdown System.

0 Answers   CCIE,


how to calibrate mass flow meter (Coriolis)? Example calibration range: 0 to 2500 kg/hr line size 3" fluid: Etheline glycol (MEG)

0 Answers   Honeywell,


Full form of KKS when use DCS.

0 Answers  


Can any body help to get Rsemulator 5000 free from internet if possible then give me any link or any help .

0 Answers   Engro,


what is preventive maintenance , explain with difination

1 Answers   Bapco Bahrain Petroleum Company,


tell me the temp range of rtd?

8 Answers  


what is the zero elevation and zero supresstion in level measurement, how can use it?

2 Answers   GAIL,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)