Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


as per standards how many neutral earthings and body
earthings are needed.please help me

Answers were Sorted based on User's Feedback



as per standards how many neutral earthings and body earthings are needed.please help me ..

Answer / purushmallya

As per ES&D and Grid code for distribution transformer 3
earthings are mandatory one for neutral one for LA and one
for matallic parts like GOS

Is This Answer Correct ?    2 Yes 0 No

as per standards how many neutral earthings and body earthings are needed.please help me ..

Answer / prashant

2NOS OF BODY EARTHINGS AND 1 NO OF NEUTRAL EARTHING

FURTHER MORE THE BODY EARTHS CAN BE INTERLINKED WHILE THE
NEUTARL HAS TO BE SEPARATE

Is This Answer Correct ?    0 Yes 2 No

Post New Answer

More Electrical Engineering Interview Questions

why dc is not given to transformer

4 Answers  


why 3 phase motors are preferable over single phase motors ?

6 Answers  


what's the exact magnitude of current, flows through Neutral?

0 Answers  


What is the field weakening mode of a ac motor?

1 Answers   L&T,


Generally the incandescent lamps in bathrooms fuse due to high voltage at night.What is the simple solution of this problem?

4 Answers  


How do we calculate transformer oil in liter from the rating of the transformer.

0 Answers   BARC,


how do you select the ct/pt rating in substation

1 Answers   Apollo, Shreem Electric Ltd, Tata Motors,


In the case of petrochemical area AC drive & AC motor is used where the speed variation is required. Why they are not Using DC drive & DC motors in such areas?

1 Answers  


CAN ANYBODY EXPLAIN WHAT ACTUALLY MEAN BY THE PHASE DEFFRENCE? R,L,C CIRCUITS?

5 Answers  


dear sir, How i calculate the 2 phase welding transformer power or kva?? kindly tell me....

2 Answers   Gedco,


we have taken HV test of 2.5 k and Megger test on 11 kv HT cable.here it shows no fault but when we are charging the same cable with 11 kv supply why the VCB 11 kv gets tripped can anybody define the possible cause of fault ?

4 Answers   MAHINDRA,


Is it possible that Generator trip but Turbine not trip.Give explanation.

1 Answers   Essar,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4453)
  • Electrical Engineering Interview Questions Electrical Engineering (16638)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)