why we set -10 volt in vibration sensor output,why not +10 volt

Answers were Sorted based on User's Feedback



why we set -10 volt in vibration sensor output,why not +10 volt..

Answer / seenu

What u said all are correct but they are using PNP Transistor

Is This Answer Correct ?    1 Yes 0 No

why we set -10 volt in vibration sensor output,why not +10 volt..

Answer / omar faruk

1. Noise are lesser added in negative voltage supply rather than positive supply.
2. To activate NPN transistor Negative Supply is mandatory.

Is This Answer Correct ?    1 Yes 0 No

why we set -10 volt in vibration sensor output,why not +10 volt..

Answer / kamrul haque

Vibration Sensor are NPN transistor so they can give negative voltage only so they are set -10 v only.its because transistor works linear in -2 to -18v so -2 to-10 8 volts same in -10 to -18 so it can measure both away and near distnce.

Is This Answer Correct ?    1 Yes 1 No

Post New Answer

More Instrumentation Interview Questions

How can we test a bently nevda 3500/42M accelerometer monitor card by simulating it with test equipment?. what king od of signal (milli volts or volts or or resistance ) we should feed in the terminals of the card?

0 Answers  


how we can calibrate level transmiiter in field?

6 Answers  


How to control flow variations in magnetic flow maters..... When i will provide proper earthing?

0 Answers   ABB, L&T,


How RAL(Rotary air lock)works in cement industry?

0 Answers   Jaypee,


what is dc moter.

0 Answers   Jindal Steel and Power, Lupin,






can any send me a forbes marshall dtron 316 manual

0 Answers  


what is function of PLC, and how is it work , explain with difination

1 Answers   Bapco Bahrain Petroleum Company,


Is it possible to drill additional gland hole in EExd or EExe JBs? What are the points to take care?

2 Answers  


WE Know that different supply voltage of solenoid valve like 24,110,220 etc..how we check the solenoid supply is 24v or 220 NOTE: No specification at device.

2 Answers   OMV,


what is sequence table in DCS . make a logic in sequence table for tripping of ID fan in Boiler(in YOKOGAWA CS 3000 DCS).

1 Answers   Yokogawa,


how feedback signal frm rtd can be use for 2 purpose, i.e. 1for local monitoring and 2nd for controlling in dcs.so how many wired RTD can be used

1 Answers  


what are the definitions of input, output, command & signal according to instruments controlled by PLC using DCS System?

0 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5084)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16631)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1094)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)