key components in hplc?

Answers were Sorted based on User's Feedback



key components in hplc?..

Answer / suresh

In HPLC solvent reservior, solvent degassing, pump, column,
injector, detector, recorder,

Is This Answer Correct ?    10 Yes 0 No

key components in hplc?..

Answer / karuna patil

Mobile phase, injector port, pumps, column, detector &
recording device.

Is This Answer Correct ?    4 Yes 0 No

key components in hplc?..

Answer / jagadish

solvent reservior,pump,degassing unit,coloumn,detector

Is This Answer Correct ?    1 Yes 1 No

Post New Answer

More Analytical Chemistry Interview Questions

How can you prepare 0.05M Ammonium acetate volumetric solution?

2 Answers  


what is the difference between BDS and ODS Columens and both are same or not

2 Answers   Intas, IPQA, Micro Labs, Vasava Engineering Private Limited,


how you establish the LOQ?

0 Answers  


Hello Dear all; I have a technical question related to analytical Chemistry, I have a sample of (40% w/w) Ferric Chloride solution (for water treatment purposes which consist a little portions of Ferrous Chloride and Hydrochloric acid. I need to know the methods to determine the percentages of each Ferrous Chloride and Chloride acid. Also I want to make sure that this solution is truly (40% w/w). So ANY CLUE !!! Thanks in advance.

2 Answers  


Why Ethanol is Used for Standardization of GC Head space?

0 Answers   Anuh Pharma, Cipla, Finar Chemicals, Hetero, Sun Pharma,






what is peak purity and its formula

1 Answers  


Why potassium hydrogen pthalate is used for perchloric acid And naoh. Why it is used for both acid and base

6 Answers   Vijayasri Chemicals,


why KBr is used in FTIR SPECTROSCOPY and why is it necessary to triturate KBr during FTIR analysis?

25 Answers   Hikal, Lupin, Wockhardt,


which functional group we can detect in IR?

3 Answers  


what is Fourier Transform

3 Answers   Graviti Pharmaceuticals, GVK,


Why do we need GC instead of HPLC? or Why do we need HPLC instead of GC?

4 Answers  


Why noise test is performed at 254 nm in calibration of HPLC system?

4 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)