Answer / karna
Diode is two terminal Device ( Anode and Cathode).It will
work only in one direction either positive or negative. If
the diode is forwad bias it will work in forward and it
will oppose in reverse bias vice-verca for Reverse bias.
SCR is three terminal device ( Anode , cathode, gate). By
using SCR we can controll the Primary circuit. It is
Control or switching operation by third terminal i.e Gate
| Is This Answer Correct ? | 8 Yes | 1 No |
Answer / faiyaz ahmad
Diode is semiconductor device its two terminal anode and cathode it will work only two direction either forward and reverse anode is Positive terminal and cathode is negative terminal the electron will be flow positive to negative according to direction if diode will be forward bias if diode will be reverse bias then just opposite and SCR is three terminal device anode cathode and gate third terminal is used to switching and amplifying the circuit
| Is This Answer Correct ? | 0 Yes | 0 No |
the pump holds on run indication into the dcs and filed local control panel remote push button condition operaton wrong like when the push button pushing conditions the pump is off and the push button release condition the pump is on totally opposite condition . And control room inside give the stop command into dcs just 1secon relay engage and again normal condition. How can I slove
Can anybody explain about wellhead control system.
WHAT IS A SYMPTOM OF FAULT WITH THE SPAN OF AN INSTRUMENT? 1)ZERO-POINT AND 100% ARE CORRECT BUT NOT A MID-RANGE. 2)ZERO-POINT IS CORRECT ,BUT 1005 INPUT IS NOT GIVING 100% OUTPUT. 3)LINEARITY PRBS. 4)1005 O/p IS CORRECT BUT ZEO POINT IS WRONG.
How to calibrate and check thermal mass flow meter of Make thermal instrument company inc model 60?
how checking is done in fiber optic cable? explain the working of RTU?
What is an antisurge control system, how it works?
what is meant by turn down ratio?
why the positioner output is 3-15psi
DC motor and DC Drives working funda?
How to adjust the zero & span of a control valve from the posiitioner(MIL)?
What is the difference between HMI and MMI?
Why mixer nd grinder Is example of constant torque load not variable torque load ???
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)