Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


How to find synchronous motor speed formula

Ns=120f/P
?....

Answers were Sorted based on User's Feedback



How to find synchronous motor speed formula Ns=120f/P ?......

Answer / k.prakashchandra

The formula for f is P/2( one cycle) x N/ 60( rps),f =NP/120
,hence N=120f/P ,where N is rpm.

Is This Answer Correct ?    23 Yes 7 No

How to find synchronous motor speed formula Ns=120f/P ?......

Answer / k.prakashchandra

What is Ns ? Is the formula required correct if Ns is rps ?

Is This Answer Correct ?    12 Yes 7 No

Post New Answer

More Electrical Engineering Interview Questions

what should be the ideal gauge of wire (In sq mm) for different loads in Ampere?

0 Answers  


Explain what is electric traction? Explain few advantages of electric traction system?

0 Answers  


How to conduct the Magnetic Balance test on Power Transformer?

0 Answers  


What is AMP and KA in a MCCB and MCB

2 Answers  


What is the Load Capacity of Panther conductor (0.2) and dog conductor (0.2) 

0 Answers   Greenko Group,


What are the different methodes for calculating the short circuit Current?

0 Answers   Equate,


The inexpensive way to improving energy efficiency of a motor which operates consistently at below 40% of rated capacity is by _____.

2 Answers   IFFCO, Sanmar,


What is primary and backup protection?

0 Answers  


WHY ARE THE LT GENERATORS SOLIDLY EARTHED WHILE THE HT GENERATORS ARE EARTHE THROUGH NGR OR NGT??

3 Answers  


what are the changes made in induction motor so that it act as induction generator

4 Answers   APPSC,


why we test the core balance of the transformer?

1 Answers  


why a single phase motor of same rating takes more amps than the three phase motor? as single phase motor at 230v takes 5amp per HP while 3 p motor takes 2.5amp per hp at 230v.

1 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)