Question { 7343 }
only three phases are coming in step down tranformers.how
to get neutral?
Answer
Is This Answer Correct ? | 3 Yes | 2 No |
Question { 4736 }
why we are having many type of vector group in the
transformer ,what is the use of it?
Answer
Is This Answer Correct ? | 1 Yes | 1 No |
Question { 11169 }
why C T secondary are rating 5A generaly .
Answer
Is This Answer Correct ? | 4 Yes | 2 No |
Question { 5987 }
Why Humming noise originated in Starter motor and how it
was generated ?
Answer
Is This Answer Correct ? | 2 Yes | 1 No |
Question { 3505 }
Generally transformers has delta primary and star
secondary. But in some transformer i saw Star primary and
delta secondary. what is the reason for chosing like this?
Answer
Is This Answer Correct ? | 2 Yes | 0 No |
Question { 3256 }
Transmission line design. Say, I have a 1MVA generator and
2 transformers that will have the same load. What would be
the proper rating of the trasformers? Is it safe to say,
that I will simply divide the total rating of the generator?
Answer
Is This Answer Correct ? | 1 Yes | 1 No |
Question { 3628 }
why supervision relay is used in incoming feeders?
Answer
Is This Answer Correct ? | 1 Yes | 0 No |
Question { 3532 }
How to connect a Restricted earth fault relay for
2000KVA,11/0.433 KV Distribution Transformer and What is
the neutral CT ratio should be selelcted for 2000 MVA
Transformer for estabilishing the Restricted earth fault
relay
Answer
Is This Answer Correct ? | 2 Yes | 1 No |
Question { 3167 }
We are having a 2000KVA DG set. It trips with Over speed
and Engne Hot when the mahine is stopped in full speed. How
shall I analyse the block load and reverse power.Is the
problem related to power factor. The machine which runs on
this DG is having all Synchronous motors with incividual
Drives.
Answer
Is This Answer Correct ? | 1 Yes | 2 No |
Can anyone explain how the vector diagram of a transformer
which doesn't have name plate be found whether it is
Dy11/Dy5/Yd11 and so on?
Answer
Is This Answer Correct ? | 7 Yes | 0 No |
Question { 3048 }
MY QUATION IS ABT THE MAIN POWER TRANSFORMER IN STEEL
PLANT , I WISH TO KNOW THAT WHY TRANSFORMER PROTECTION NOT
TRIP AS CABLES ON THE SECONDAY SIDE IS WATER COOLED.
TRANFORMER DETAIL
NORMAL KVA--150 KVA
PRIMARY VOLTAGE --34.5 KV
SEC.NO-LOAD VOLTAGE---1.290-908-690V ( WITH PRIMARY DELTA
CONNECTED)
CONNECTION--D/d (EXTERNAL CLOSED)
CONSTANT RATEING FROM--1.290-908V
CONSTANT CURRENT FROM--908-690
VECTOR GROUP--D III
Answer
Is This Answer Correct ? | 3 Yes | 0 No |
what is the difference between the 94 lockout relay and 86
lock out relay. I have noticed that the 94 lockout relay is
activated when the distance realy is activated and 86 is
activated when the 87T differential is activated. but why
can't the same lockouts be used for both the protection
schemes
Answer
Is This Answer Correct ? | 2 Yes | 12 No |
Question { 25212 }
why rating of motor in HP?
Answer
Is This Answer Correct ? | 0 Yes | 0 No |