Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


In case of HPLC coloums what is the difference Between C8 &
C18 coloums & how can we select difference type of coloums
like Inertial ODS , Hypersil BDS , ODS etc.?

Answers were Sorted based on User's Feedback



In case of HPLC coloums what is the difference Between C8 & C18 coloums & how can we select..

Answer / paresh jobanputtra, piramal(ah

in case of C8 column,C8 carbon chain is attached to the packing material
and in case of C18(ODS) column, C18 carbon chain is attached to the packeting material.
eg. OH
ยก
OH-SI-O-C8 orC18
!
OH
Some names of specially treated stationary phases:suitable for separation of BASIC compds.
like Inertsil:"Inert towards bases"
BDS :"Base deactivated silica"
different make columns have different characteristics
like different Carbon load,Specific pore volume(empty spaces betn particles),Specific surface area,Ligand density etc.
If the carbon load is high it means specific pore volume is lesss so retained capability of packing material is high so capacity factor is high. so retemtion is better of this column.
and selection of column is depends on nature of product, and no of trials in developement.

Regards,
Paresh Jobanputtra.

Is This Answer Correct ?    26 Yes 3 No

In case of HPLC coloums what is the difference Between C8 & C18 coloums & how can we select..

Answer / balaram naidu.m

HPLC in mainly two types of columns is used
These are (1)Normal phase columns
(2)Reverse phase columns

C18 And C8 COLUMNS both are reverse phase columns.
C18 columns is highly polar columns compare with C8 columns

C18 Column Structure is OH-Si-C18 linkage

C8 Column Structure is OH-Si-C8 linkage

These columns is depend up on the compound natchere

ODS means OCTA DECYLE SILANE. This types of columns
is used mainly acidic nacture compounds.

BDS means BASE DEACTIVATED SILANE. This types of columns
is used mainly basic nacture compounds.

Is This Answer Correct ?    19 Yes 10 No

In case of HPLC coloums what is the difference Between C8 & C18 coloums & how can we select..

Answer / pharmainterview

C8- C8 Carbon chain is attached to silica
c18- C18 Carbon chain is attached to silica.

There are many manufacturer who will prepare c8 or c18
column. Even though the basic concept is same for all,
there are some differences like
1.pore size
2.particle size
3.free silanol
4.end capping
5.silica purity etc

Based on our sample properties and suitability we can selct
a column after different trials.

Regards
pharmainterviewquestions.blogspot.in

Is This Answer Correct ?    9 Yes 1 No

In case of HPLC coloums what is the difference Between C8 & C18 coloums & how can we select..

Answer / ravendranadhareddy

I think both columns polar columns
BDS column based deactivedd silane this hair ph basic nature
ODS Column Octa decyle silane acetic nature ph 7 below

Is This Answer Correct ?    4 Yes 6 No

Post New Answer

More Analytical Chemistry Interview Questions

How NMR spectra can be calibrated in presence or absence of TMS?

1 Answers  


What is the reason for using the 900ml of dissolution medium

16 Answers   Cipla,


for which type of applications gas chromatography is used?

2 Answers  


how require to select dissolution media? what is discrimination?

0 Answers  


how calculate column dead volume in hplc ?

3 Answers   Torrent Pharma,


Why pH range is maximum 14.0

6 Answers   UPL,


What is the diffrence between the performing of LOD ordinary drying at voven and vaccum method.

4 Answers   Apex,


What is Delay & Dead Volume

2 Answers  


In the test for control of absorbance in UV calibration why do we use only potassium dichromate and what is purpose of taking a specified amount of 57.0-63.0mg?

1 Answers   Reddy Labs,


what is the general mechanism of high performance liqiud chromatography?

7 Answers   Ajanta Pharma, Amneal Pharmaceuticals,


why we are using buffer solutionas as a mobile phase in hplc.

2 Answers  


What do you mean by potency in Analytical industry

3 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)