Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In case of HPLC coloums what is the difference Between C8 &
C18 coloums & how can we select difference type of coloums
like Inertial ODS , Hypersil BDS , ODS etc.?

Answer Posted / balaram naidu.m

HPLC in mainly two types of columns is used
These are (1)Normal phase columns
(2)Reverse phase columns

C18 And C8 COLUMNS both are reverse phase columns.
C18 columns is highly polar columns compare with C8 columns

C18 Column Structure is OH-Si-C18 linkage

C8 Column Structure is OH-Si-C8 linkage

These columns is depend up on the compound natchere

ODS means OCTA DECYLE SILANE. This types of columns
is used mainly acidic nacture compounds.

BDS means BASE DEACTIVATED SILANE. This types of columns
is used mainly basic nacture compounds.

Is This Answer Correct ?    19 Yes 10 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to get accurate result for Residue on evaporation in purified water

1697


why does used dry caffien in HPLC calibration?

2079


What is related substance by HPLC impurity limits as per USP?

1154


if content uniformity passing but dissolution varrying then what is next step?

936


What is the acceptance criteria for moisture balance when calibrated with sodium sulfate

2090


i want model written test paper for the post of analyst in IOCL(indian oil corporation ltd) any one pls help me

2780


what is definition of validation? which components are followed give detail?

2448


using gradient pressure in gas chromatography are not ?using gradient pressure why

3440


in gas chromatography what is the difference between gas flow rate and average linear velocity ?

2652


What is delay volume?

1433


what is mean by dissolution biowaiver study?

995


Why potassium dichromate is used in calibration of uv?

2038


What are the primary considerations in extractables and Leachables ?

2318


In HPLC Calibration, On which basis RSD Limit of noise test is fixed (NMT 33.0 % )

3552


how you establish the LOQ?

842