How the Transformer oil testing is done & Why oil dielectric goes LOW & what is solution for that ??
NTPC,
3 11600What is the function of Lightning Arrester & Wavetrap in Power system ??
ABB, Bhel, Energy Infratech, Infosys, NTPC,
18 76348Why Power generation in India is at 50Hz while in America its 60Hz so is there any advantage/Disadvantage of this ??
Australia Visa, College School Exams Tests, Fiat, InfoPlus, L&T, NTPC, TCS,
38 80209which Machine u will prefer to use at place where Flammable gases are coming out & why ??
NTPC,
6 8488Why Human body feel Electric shock ?? n in an Electric train during running , We didnt feel any Shock ? why
13 45238What is the formula for calculating Transformer Losses & Efficiency. I want to compare the Transformer efficiency at different loading condition.
6 157569i had aplied Hindustan Petroleum corporation limited for the post of maintenance technician -Electrical,i want model questions,if anybody have please send it or please advice?
1430Post New Electrical Engineering Questions
what is through fault?
How to calculate Number of Earthing Pits....???
What it the purpose of parallel phasing transfomers??
How many methods use the load flow solution?
WHAT IS MEANT BY OVER EXCITATION IN GENERATOR TRANSFORMERS? DESCRIBE IT.
Why efficiency in thermal power plant is low?
How are load losses and no-load losses measured at site in a DG set?
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?
1))why we run three phase or three different circuit from a single conduit 2)) why not two circuit of different phase run in same conduit?? and why we run same three cicuit of same phae run in single conduit??
What is Load sharing of Transformer ?
In the N-series schneider reclosers. What is the difference between current during fault time and current at tripping? This appears in the Event log in an event of a trip out.
What is effect on in zone and out zone fault if CT chosen for phase side is Vk/2<5mA and Neutral side is Vk/2<15mA on REF protection of Transformer
How to know the following data of synchronous generator 1. D-Axis Unsaturated Reactance 2. D-Axis Unsaturated Transient Reactance 3. D-Axis Unsaturated Sub - Transient Reactance
how solar power plant energy meter multiplication factor
What is the pro & con of having 11kv & 33kv incoming, and what is the adv & disadv. of converting from 11kv to 33kv.