While connecting bulb in Series/Parallel,there is any difference in glowing

3 4985

When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<

Lupin,

1769

Why the meters sonnected to metering core of CT are not damagedon event of a fault??? Explain the phenomena??

Schneider,

1 4384

Does the isolator has a making capacity????????

2 4553

How to determine earth fault level to set relay for a normal distribution system of 11 kV , 100 A load????????

TCS,

1 3654

why is the number of turns different in current and potential coils of wattmeter..?

1 2975

Why the Transformer connection is changing in different transformer?(Like Star & Delta,Delta & Delta,Star & Star,Delta Star) From that connection where it is used?

2 6250

1)What will happen when 240 VDC supply is connected to 240VAC supply(DC supply +ve is connected to phase of AC supply & DC supply is to neutral of AC supply). 2)Also what will happen when 240 VDC supply is connected to 240 VAC supply in reverse polarity as of Sr. No 1.

2 4168

What will happen when more than one star neutral points at same voltage level are connected to earth by metallic conductor?

TCS,

1 3491

What is the unit of inertia constant of rotating machines? Which has more inertia constant between turboalternator and hydroaltermanor and why?

2 15782

Why CT secondary should not left open??????????

2 6219

for a 11kv transmission line what capacity of CTs & PTs are required?

4 9816

what is method for testing CT

DCM,

1703

Can the efficiency of transformer be measured with the help of wattmeter readings taken at primary and secondary side? Support the answer.

2 3916

Classical power system stability was mainly focussed on rotor angle stability but modern power system stability has more focus on voltage stability.Why?

4 6491


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

Mention the methods for starting an induction motor?

732


plz send me HPCL apptitude paper.. maulik_elect@yahoo.co.in

1739


Why using synchronising methed in DG's sets?

1810


what questions are asked in the interview for the post of an electrical maintenance engineer in FMCG companies?

2257


What is resolver and glass scale in CNC how they work?

1861






What are the special cables required for explosion proof wiring?

3068


What is Annunciation?

1644


How the over load setting for HT Motors calculated-provided in Numerical Relay

1303


what is the differencce inn series and cascade connection??

4357


Name the test signals used in control system

888


What is the physical significant of power factor?

1569


Advantage of LT panel vs HT panel

2424


The capacitive reactance of a capacitor of 1/(2(PI)) F at 10^3 H is

1488


State thevenintheorem?

672


why voltage form factor of PT are increase , when it is ecpected heigher spikes in system. how it is calculated.

1755