Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

While connecting bulb in Series/Parallel,there is any difference in glowing

3 5902

When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<

Lupin,

2109

Why the meters sonnected to metering core of CT are not damagedon event of a fault??? Explain the phenomena??

Schneider,

1 5232

Does the isolator has a making capacity????????

2 5266

How to determine earth fault level to set relay for a normal distribution system of 11 kV , 100 A load????????

TCS,

1 4151

why is the number of turns different in current and potential coils of wattmeter..?

1 3574

Why the Transformer connection is changing in different transformer?(Like Star & Delta,Delta & Delta,Star & Star,Delta Star) From that connection where it is used?

2 6932

1)What will happen when 240 VDC supply is connected to 240VAC supply(DC supply +ve is connected to phase of AC supply & DC supply is to neutral of AC supply). 2)Also what will happen when 240 VDC supply is connected to 240 VAC supply in reverse polarity as of Sr. No 1.

2 4806

What will happen when more than one star neutral points at same voltage level are connected to earth by metallic conductor?

TCS,

1 4091

What is the unit of inertia constant of rotating machines? Which has more inertia constant between turboalternator and hydroaltermanor and why?

2 16562

Why CT secondary should not left open??????????

2 6940

for a 11kv transmission line what capacity of CTs & PTs are required?

4 11058

what is method for testing CT

DCM,

2106

Can the efficiency of transformer be measured with the help of wattmeter readings taken at primary and secondary side? Support the answer.

2 4951

Classical power system stability was mainly focussed on rotor angle stability but modern power system stability has more focus on voltage stability.Why?

4 7407


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

which one is more efficient, torq, power & ecnomy with the same frame size AC motor / DC motor?

2141


in the case of 6.6kv motor starter combination contain fuses on it VCB. but in 11KV motor starter combination Fuses are not using in it's VCB why?

2237


what is the minimum (Common factor) insulatin resistance of the following a, 4mm sq wire b, cable from 50 mm sq to 800mm sq

2055


If I want to buy a new Xformer for my plant what are the main parameter will I need to check?

1861


I want formula to calculate cable size as per load given in length & amp. I searched many sites but didn't right answer. Please reply me asap.

1431


if 3400kw slipring motor rotor shorting done and motor started on mv drive ,what will be the rotor shoring current

1640


working principle of AC Servo Motor with its construction

8847


If we want to change a contactor of faulty one what are the conditions want to fullfil

1954


A 11KV, 1200 A breaker combination fixed in a cubicle for HT motor.Is normally for 11 KV motor fuse is using? if Yes, What range fuse is required?

1918


What should be the amps for a MV fuses for transformer 630kVA 20(10)/0.4 kV

1992


Testing report of Earthing of 3.15 MVa PTR.

2533


how to calculate power consumption in slip ring motor at different step

2188


What is the importance of earthing?

1069


what happens when dc generator coupled with cycle shaft.also explain what happens when its loaded

2096


pls someone send me sample question papers along with the key.thanks in advance

2338