the inertia constants of two machines are respectively 30and 42 MJ per MVA.when the change in frequency due to change in load in first machine is 12 Hz,the change in second machine frequency will be?
1 5871how to interlock 2 incomer,1 buscoupler MCCB,like we interlock an ACB... pls answer this question and if possible send me the ckt diagram..
2 14822Good Evening all.My question is - For a feed water line to an equipment if i need to measure the flow we will use orifice /magnetic/vortex depend on cost/spec.If i need to measure a ''Alarm''signal and ''Interlock'' from one point i think we can use orifice type in one location with 2 different tapping points - one for alarm and one for an interlock to flow valve..If in case i need to have both these signals(Alarm & interlock) from magnetic flow meter,is it possible??will 2 seperate sensors will be located inbuilt r we can program it ??..i thk we can have one transmitter with these 2 signals...need to know any technical issues are there?pls clarify
3 4240
In UMTS, which will control RRC protocol??
a solid steel rod length 2m dia and 20mm vertically hangs from celling and has a collar firmly atteched to it. above the collar an annular rubber washer of 40mm th. having stifness k = 5n/mm is placed. determine maximum stress in the rod caused by mass of 5 kg falling through a height of 1.2m.
what is the procedure for auto tune in masoneialn 12300 series displacer type transmitter?
For RCD (Residual current device) Icu is defined. How i can find Ics for them?
How dia computation perfomed in cold rolling mills .
how is the config take place and from reciever side how will process the data into internal table
What are thermal neutrons ?
what is the responsibility of C license holder in industry?
placement paper samples of mspl company
distance between the power generation and the distribution to the application is fixed or vary
solar cooker based on the principle
How many types of instrument cables are there?
We are using Rosemount 5400 series Radar Level Transmitters in all types of Sump Applications having oily water hdrocarbon petrochemical nature. What we are facing the problem frequently is that always getting reading frezzed at some value. If we do power recycling , sometimes it is working . then making same freezing problem. If anybody faced before such type of problem and also having solution , Please give the answer.
Give an introduction to bourden pressure gauge?
Prepare a Schedule for a Highrised building from starting stage to Handover?