How we can test the Smoke Detectors????

Answers were Sorted based on User's Feedback



How we can test the Smoke Detectors????..

Answer / ravi

By Smoke Simulation Method.......

Is This Answer Correct ?    10 Yes 4 No

How we can test the Smoke Detectors????..

Answer / joy

simplest way is apply a certain volume of smoke in a room
where the detector is placed that would be enough to trigger
the SD to send an alarm signal to its control panel that is
if this is not just the battery operated one.

Is This Answer Correct ?    3 Yes 0 No

How we can test the Smoke Detectors????..

Answer / kannara

You can use magnet for test smoke detectors.hold a magnet near to the detector,the detector will activate with in seconds and give fire signal to main panel

Is This Answer Correct ?    2 Yes 1 No

How we can test the Smoke Detectors????..

Answer / arun kumar .k

In smoke detector uisng the Bymetalic strips
It is like nc/no contact when temprature increase it will
trigger the hooter circuit

Is This Answer Correct ?    0 Yes 1 No

Post New Answer

More Electrical Engineering Interview Questions

ct connection of energy meter

1 Answers  


What is reason of rating of transmission line multi pal of 11 like as 11/33/66/220 ? Why not use 75 kv 23 kv line in power system ?

1 Answers   Apollo, Balco, Bhel, Vardhman,


when we increased the current what do ?

0 Answers  


State how to produce a constant rotating field by application of alternating currents to stator armature of a three-phase squirrel-cage induction motor

1 Answers   Jindal,


what is impedance?

1 Answers   PWD,


how to calculate no load losses units comsumed by transformer

2 Answers   MRF,


HELLO EVERYONE, I RECENTLY HAVE FOUND ONE PROBLEM, I WAS TAKING NO LOAD TRIAL OF AN HT MOTOR 920 MOTOR , 1440 RPM , 6.6 KV, WITH AUTO TRANSFORMER. AT 450 V, LOAD WAS 40 AMP AND SPEED WAS 250 RPM. BUT AS WE INCREASE VOLTAGE FROM 450 TO 480V, LOAD BECOME 41 AND SPEED REDUCED TO SOME RPM . SO WHICH PHENOMENON ACTED HERE FOR REDUCING SPEED.?? AND IS IT HAPPENING ALWAYS OR IT IS RARE? I ALSO HAVE FACED SUCH PROBLEM WITH FEW LT MOTOR ALSO.

1 Answers  


what is reactive power?

8 Answers  


what is transformar load balancing ?

2 Answers   L&T,


why we need to us lenz's law for synchornous motor

1 Answers   Tata Elxsi,


What is transposition in a transmision line?

2 Answers  


Electricity sometimes can be dangers , sometime got shoked form it . It is because of volatge or Current

6 Answers   Kirloskar,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4453)
  • Electrical Engineering Interview Questions Electrical Engineering (16638)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)