Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


which motor is suitable for traction? why?

Answers were Sorted based on User's Feedback



which motor is suitable for traction? why?..

Answer / bhupesh

DC series motor, always!!
because of its high stating torque and speed control..
But now a days, like in Delhi metro squirrel cage induction
motor is used becoz of its compact design, less maintenance
and regenerative current system.
also some improvements are made for better speed control..

Is This Answer Correct ?    9 Yes 6 No

which motor is suitable for traction? why?..

Answer / hemlata

Series wound dc motor due to it has low resistance field and armature winding (according to ohms low I=V/R) advantage high current magnetic field inside the motor strong,produce high torque (turning force)

Is This Answer Correct ?    2 Yes 0 No

which motor is suitable for traction? why?..

Answer / himabindu

D.C. Series motor since it has a high starting torque

Is This Answer Correct ?    2 Yes 0 No

which motor is suitable for traction? why?..

Answer / fulchand mahato

(a) →high starting torque.
(b)→better speed control.
(c)→low maitanance cost.

Is This Answer Correct ?    1 Yes 0 No

which motor is suitable for traction? why?..

Answer / surender kumar

Series motors are widely being used in traction systems, due to good starting torque ,speed controlling quality.
In general terms series motors are starting on load and performing great in compare to rest motors.

Now induction motors are also being apply in traction with SCR it is recent development.

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Electrical Engineering Interview Questions

11 KV Power cable end earth connection insulation got burned wht is the reson pl give the resons

2 Answers  


How to increase home power factor? Can we connect capacitor directly? How to select capacity of capacitor?

5 Answers  


what is the mechanism of operation of brushless dc motor why is it more wexpensive then ordinary permanent magnet motors

0 Answers   Lanco,


Are we do it in single transformer with dual primary as 11 KV and 33 KV and constant output as 415 Volts?.

1 Answers  


What is the name of oil which is used in transformer?

3 Answers  


if the diameter of a conductor is 'R' then what is the distance between two bundle conductor in a phase?

1 Answers   NTPC,


what is the difference in MCB, MCCB, RCCB, ELCB, & MPCB (motor protection circuit bracker)

12 Answers   Afcons, Bhel, CIHSR, DCS, IOCL, L&T, Lupin, Siemens,


If there is major % of Voltage harmonics in the system, how can it be control or reduced?

0 Answers   JCN, Wipro,


Showing results for capital, machinery, stock,wages, carriage in words, salaries, factory rent, repairs, fuel and power, buildings, debtors, sales, purchases, creditors, return outwords, return inwords, drawings, discount allowed, discount receivable, office expenses, bills payable, bills receivable, cash in hand, cash at bank, office rent comes under debit or credit

0 Answers  


1.Is there any difference between terminologies,HT-HV &LT- LV? 2.What is the highest transmission voltage level in india?

5 Answers  


what are symmetrical and non symmetrical components in electrical installation.

0 Answers  


An 11kv system consisting of an underground cable to a sub station about 300 meters away was shut down for about 10 hrs. On energising, it tripped off on earth fault about 10---20 mins later 6 times but since than it is not tripping.its already 3 weeks now. The SPAJ was found to be fine. what could be the cause.No test had been done to determine the cause of the trippings till now because of demand.

2 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4453)
  • Electrical Engineering Interview Questions Electrical Engineering (16638)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)