what happens if we give 1-ph supply for 3-ph Bridge rectifier...??

Answers were Sorted based on User's Feedback



what happens if we give 1-ph supply for 3-ph Bridge rectifier...??..

Answer / k.prakashchandra

It will work as 1 phase rectifier if one of the other two phases is replaced with neutral

Is This Answer Correct ?    7 Yes 1 No

what happens if we give 1-ph supply for 3-ph Bridge rectifier...??..

Answer / su raj

it will act as an 1 ph rectifier if anyone of other 2 lines of 3 ph rectifier is connected with nutral.

Is This Answer Correct ?    2 Yes 0 No

Post New Answer

More Electrical Engineering Interview Questions

What are the consequences in using existing step up transformer (primary 6.6kv/175A, secondary 480v/2405A) for step down transformer to have a 6.6kv output?

1 Answers  


In a company has been installed an analog amperemeter, this company was suplied by generator X, there is no problem in the ampere meter, rigth now this company's supplied by generator Y then the pointer in amperemeter vibrating. What happened? Why? Thank's

2 Answers  


when is safety goggles use mandatory?

3 Answers  


Why the Motor takes High Current in Starting time?

5 Answers  


1.where in India the maximum transmission voltage is operated? 2.what the methods are used to cool down the transformer?give the specific ratings of the transformer & specific cooling process. 3.how zero & negative sequence reactances are formed in a rotating machine when fault occur in the system?

2 Answers   IES,






what is the formula for calculating of dielectric strength of transformer oil.

2 Answers   Bhel,


Why the Transformer connection is changing in different transformer?(Like Star & Delta,Delta & Delta,Star & Star,Delta Star) From that connection where it is used?

2 Answers  


I have 2 Nos of 2500kVA 33/0.415V cast resin transformers. How to decide on ampere rating of HT Panel? Also advise me how many panel RMG i have to consider whether 4 panel ok?

1 Answers  


What is EHT tariff or Power factor Tariff ????

0 Answers   KSEB,


Q. calculate the value of the resistor to be connected in series with a 100W; 230V lamp so that the wattage of the lamp is reduced to 35W

8 Answers  


all the technical question with answers pleas send your email id ramar_eee@yahoo.com

0 Answers   RRB,


what is a speed of rotor when we give supply to stator of 50hz and as well as rotor of 60hz of an induction motor?????

0 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)