Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


differnc btw c18 and c-8 column

Answers were Sorted based on User's Feedback



differnc btw c18 and c-8 column..

Answer / jaya krishna priya.g

C-8 and C-18 are the columns used in the reverse phase of HPLC. The difference b\w the carbon chain length that is attached to the silica surface.C-8 has a packed material composed of silica particle of carbon units and C-18 is coated with hydrophobic units.

Is This Answer Correct ?    11 Yes 0 No

differnc btw c18 and c-8 column..

Answer / satyabana sahu

C18 is more hydrophobic then C8 because it has longer carbon chain. C18 is faster separation then C8. C8 may be used instead of C18 when shorter retention times are required.
C18 is often called the "traditional reverse phase matrix". Because it has the highest degree of hydrophobicity, C18 silica gel interacts with the widest range of compounds and the interactions are generally more pronounced.

Is This Answer Correct ?    6 Yes 0 No

differnc btw c18 and c-8 column..

Answer / paddy

Polarity decreases as carbon chain increases

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

what is the definition of limit of stray light in UV calibration

1 Answers   FDC, Zydus Cadila,


priciple of gc & hplc? (properly describe)

2 Answers   Cadila, Cipla, Reddy Labs,


why should we perform dissolution PVT calibration only by UV spectrometer, not by HPLC ?

0 Answers  


What should be the level/ Percentage of Arsenic in Arsenic free zinc.

0 Answers   FDC, Laurus, Pharmaceutical,


in pentoperazole capsules usp why assay value is substract from dissolution

1 Answers   Ranbaxy,


why octanol used to determine the partition coefficient ?

0 Answers  


What is Diffidence between Normal Detector and PDA Detector?

2 Answers   Aurobindo,


how to develop the icp ms method? Application of icp ms?

0 Answers  


Why we are using a Kf Factor range 4 to 6

7 Answers  


Qc interview questions

0 Answers   Apotex,


WHAT IS THE DIFFERENT BETWEEN PURITY, POTENCY AND ASSAY

6 Answers   Glochem, Hetero,


why we do the calibration of limit of stry light in hplc & uv

1 Answers   Cipla,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)