Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


differnc btw c18 and c-8 column

Answers were Sorted based on User's Feedback



differnc btw c18 and c-8 column..

Answer / jaya krishna priya.g

C-8 and C-18 are the columns used in the reverse phase of HPLC. The difference b\w the carbon chain length that is attached to the silica surface.C-8 has a packed material composed of silica particle of carbon units and C-18 is coated with hydrophobic units.

Is This Answer Correct ?    11 Yes 0 No

differnc btw c18 and c-8 column..

Answer / satyabana sahu

C18 is more hydrophobic then C8 because it has longer carbon chain. C18 is faster separation then C8. C8 may be used instead of C18 when shorter retention times are required.
C18 is often called the "traditional reverse phase matrix". Because it has the highest degree of hydrophobicity, C18 silica gel interacts with the widest range of compounds and the interactions are generally more pronounced.

Is This Answer Correct ?    6 Yes 0 No

differnc btw c18 and c-8 column..

Answer / paddy

Polarity decreases as carbon chain increases

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

what is the difference betwen the analytical column & peparative column?

4 Answers  


How we can determine OOT limit in Stability

2 Answers   MSN Pharma,


use of stry light

1 Answers  


why we use only vanilline , acetanilide,& caffeine For the Calibration of melting point appartus?

7 Answers   Reddy Labs,


in sampling of raw material which side is pasted sampled labels

0 Answers  


what is rs test why we are perfoming rs test

2 Answers  


Why Deuterium lamp is used as UV light Source for UV.

4 Answers  


Why do we use KCl ,K2Cr207,Toulene & Halonium oxide for the caliberation of UV

2 Answers   Apotex,


What is difference between FID and TCD in gas chromatography

1 Answers   Cipla, VPCPL,


why use k2cr2o7 , kcl h2so4 in uv calibration

1 Answers   DRL, GVK,


Can anybody tell me how to measure Redox potential in an aerobic matrix, for e.g., soil etc.?

2 Answers  


difference between instrumenent and equipment

6 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)