Why potassium hydrogen pthalate is used for perchloric acid
And naoh. Why it is used for both acid and base

Answers were Sorted based on User's Feedback



Why potassium hydrogen pthalate is used for perchloric acid And naoh. Why it is used for both acid ..

Answer / ronakpatel

because KHP contains -COOH and -COOK groups in its structure,
so when we it standarize whith PCA -COOK will react and
when it standarize with NaOH, COOH group will react

Is This Answer Correct ?    43 Yes 2 No

Why potassium hydrogen pthalate is used for perchloric acid And naoh. Why it is used for both acid ..

Answer / dr. a. bera

It acts both as a acid & base

Is This Answer Correct ?    34 Yes 9 No

Why potassium hydrogen pthalate is used for perchloric acid And naoh. Why it is used for both acid ..

Answer / mahesh.duggirala

accually PHP nature is acidic(pH:4.5)..so we use for
standerdization of NaOH.but in HClO4,we standedize in
presence of Acetic acid..Acetic acid & PHP combined to form
conjugate base.that conjugate base react with HCLO4
solution..in HCLO4 standerdization

Is This Answer Correct ?    11 Yes 8 No

Why potassium hydrogen pthalate is used for perchloric acid And naoh. Why it is used for both acid ..

Answer / sun

only one person knows ans
person name parshant kamalapurkar DGM QC polydrug

Is This Answer Correct ?    0 Yes 2 No

Why potassium hydrogen pthalate is used for perchloric acid And naoh. Why it is used for both acid ..

Answer / sandip bhasme

KHP is available in puriest form 99.9%. Is stable in normal
storage conditions. is used as primary standard for standard
alkalies.

Is This Answer Correct ?    1 Yes 15 No

Why potassium hydrogen pthalate is used for perchloric acid And naoh. Why it is used for both acid ..

Answer / gopal

Potassium hydrogren phthalate is easily available in pure
form. It is not hygroscopic in nature.

Is This Answer Correct ?    5 Yes 20 No

Post New Answer

More Analytical Chemistry Interview Questions

IN DISSOLUTION S1 STAGE 1 BOWL GOT 52%(Q POINT IS 80%)WHAT WE HAVE DO

9 Answers  


Why we have to take 42gm of sodium hydroxide instead of 40gm for preparation of 1M Sodium hydroxide as per Pharmacopia? Whether it means the formula for calculating molarity was wrong? 

5 Answers   Claris Otsuka, Ranbaxy,


what is the difference between M.C and LOD

21 Answers   Aurobindo, Cipla, Laurus, Matrix, Synthokem Labs,


what is the dipolement and how it is related to IR

1 Answers   AJ Square Inc, Aurobindo,


only one end point is possible for citric acid and we get 2 end points for di acid why?

3 Answers   Reddy Labs,






what is the identification test of volatile substance? what is volatile compound?

1 Answers  


What is the Defination of Tapdensity ?

4 Answers   Dr Reddys, R L Fine Chem,


How will decide to use HPLC OR GC for developing method for unkown compund

5 Answers  


what are the normalisation, internal standard and external standerd methods in HPLC.

2 Answers   GVK,


why we inject sample TWICE in ASSAY by HPLC analysis but in RS once?

4 Answers   Aurobindo, DRL, Neuland,


effect of pore size, pore volume, partical size, column length, carbon load on retention time? what is carbon load? what is the use?

0 Answers  


why we wre doing linearity siudiec in hplc method validation

3 Answers   Cipla,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)