WHAT IS MEANT BY SLIP , WHERE IT OCCUR

Answers were Sorted based on User's Feedback



WHAT IS MEANT BY SLIP , WHERE IT OCCUR..

Answer / chirag

slip occurs in electrical motor.
Slip desribed as differance between syncrinous speed and
rotor speed.

%Slip=Ns-Nr/Ns

Where,
Ns=Syncronous speed
Nr=rotor Speed

Is This Answer Correct ?    7 Yes 0 No

WHAT IS MEANT BY SLIP , WHERE IT OCCUR..

Answer / ritesh

slip is relative speed between synchronous speed & rotor speed
s= Ns-Nr/Ns

Is This Answer Correct ?    2 Yes 0 No

WHAT IS MEANT BY SLIP , WHERE IT OCCUR..

Answer / dinesh

the difference between the synchronous speed of the stator
and rotating speed of the rotor is called slip

S =Ns-Nr/Ns

Is This Answer Correct ?    1 Yes 0 No

Post New Answer

More Electrical Engineering Interview Questions

how to compare with Relay settings for HT&LT panels, RMU panel, and PSS CSS transformer?? 1) Load amps, 2)Tripping time, 3) CT ratio, 4)Cable size 5) Transformer KVA rating 6) transformer full load amps

0 Answers  


how could we calculate the no of outgoings from a 800 watt distribution board

0 Answers   United Engineering,


in electrical fire which group fier Extinguisher as used

6 Answers  


How to setting the volume of RTCC panel AVR (11kv) controller

0 Answers   CNF Automotive India,


Main CT ration is 400/5, meter CT ratio is open type: -/5A. What is the Multiplying factor of the meter, considering same PT ratio.

1 Answers  






which tap of the transormer you will use in critical condition(worst)?

1 Answers  


What are chief characteristics of state-space method and its techniques ?

0 Answers   Limton,


in a transmission line if the load is suddenly increased in the receiving end of the system the phase shift will ?

1 Answers  


What is a transductor ?

2 Answers  


what is the function of bearing in dc mchine" and where it is placed

0 Answers  


IN 3 PHASE INDUCTION MOTORS SOMETIMES COPPER BARS ARE PLACED DEEP IN ROTOR WHY..?

3 Answers   ONGC,


meter ratio is 100/5 CT ratio is 125/5, when the ratios changes i.e., CT ratio is 125/5 meter ratio is 100/5 what is the MF in boths conditions?

1 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4452)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)