Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Why carbon brushes are used in motors?

Answers were Sorted based on User's Feedback



Why carbon brushes are used in motors?..

Answer / nagendra murthy

any DC motor or generator will need to have a commutator. A
commutator is a device used to change the direction of
current flow through the motor. The reason a cummutator is
needed is because a DC current in a magnetic field can only
turn the motor through 180 degrees, after which the force
will cause the motor to return to a fixed position. In order
to make the force turn the motor the current needs to be
changed every 180 degrees so that the force will act in the
opposite direction, spinning the motor around. This is
achieved using a commutator. The commutator is normally a
device which brushes against terminals in the motor. As the
motor turns the terminals in contact with the brushes
change, and so does the current.

Is This Answer Correct ?    18 Yes 2 No

Why carbon brushes are used in motors?..

Answer / paragbajpai

1.carbon brushes are used as it is having high resistance so
that time constant will be reduced that means commutation
will be improved.
2. it has self relieving property

Is This Answer Correct ?    6 Yes 0 No

Why carbon brushes are used in motors?..

Answer / k.prakashchandra

1.A good conductor 2.has desired hardness 3 can be easily
Reshaped 4.cheap 5. easily available 5. does not corrode 6.
cleaning is easy 7.weather resistant 8 not inflammable etc

Is This Answer Correct ?    6 Yes 3 No

Why carbon brushes are used in motors?..

Answer / sarath k

the carbon brushes are used as commutators because of resistance commutation and the carbon has self polishing property

Is This Answer Correct ?    4 Yes 4 No

Why carbon brushes are used in motors?..

Answer / satheeshkumar

Only The carbon having possessing the negative temperature coefficient This is the main reason using for commutation porpose (The ratio of increasing resistance per degree centigrade o the resistance at 0 degree centigrade) dippend the carbon inverse action must take place

Is This Answer Correct ?    1 Yes 1 No

Why carbon brushes are used in motors?..

Answer / gautam

carbon acha nahin hota hai

Is This Answer Correct ?    0 Yes 9 No

Post New Answer

More Electrical Engineering Interview Questions

What will be the full load current of 60KVA UPS. Suggest for this formula.

8 Answers   ABC, Sodexo,


How Calculet The UPS AH In Load

0 Answers  


How to checking sld drawingas and control drawings

1 Answers  


IN A SMALL D.C GENERATOR, IF WE REPLACE THE LAMINATED CORE ARMATURE WITH A WOODEN BLOCK OF SAME SIZE & SHAPE AND WIND WIRES WOUND ON THE SLOTS OF WOODEN ARMATURE AND CONNECTED TO THE COMMUTATOR.COMMUTATOR IS FITTED WITH BRUSH TO RECEIVE INDUCED E.M.F.WHETHER E.M.F GENERATED OR NOT?

3 Answers  


how to setting voltage RTCC panel

0 Answers  


what is the ground clearance of 400KV transmission line?

9 Answers   Power Grid, wbsedcl,


How to calculate the voltage drop of 4 Core 50 Sqmm SWA cable for a distance of 350 mtrs and what can be the maximum load connected to it?

3 Answers  


why receiving end voltage increases in a system when capacitive load is added

1 Answers  


What is the unit of attenuation?

0 Answers  


Draw SLD feeding from the SS up to distribution board of the load, calculate cable size, breaker sizes, and meter for the following case: Ground Floor: electric room, pump room, 5 shops, each is 15 KW First Floor: 5 shops, each is 15 KW Second Floor: showroom 30 KW Service Loads: water pump 3 KW (3ph) , fire pump 3 KW (3ph), and one DB service 12 KW (3ph).

0 Answers   FEWA, HMK,


why do we measure VIBRATION in -24vdc and why we adjust gap voltage -9vdc to 10-vdc? i am trying to get this information since 5 years, yet i haven't get reliable answer, i hope i can get from you.

0 Answers  


i have attended the interview on 4th June,08 at Kolkata in IOCL, can anybody tell me what is its result

0 Answers   IOCL,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4453)
  • Electrical Engineering Interview Questions Electrical Engineering (16638)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)