why micro controller 8051/52's clock frequency is
internally divide by 12 ??

and why it is further divide by 32 in UART serial
communication ??



why micro controller 8051/52's clock frequency is internally divide by 12 ?? and why it is..

Answer / arun

to execute one bit of instruction the microcontroler takes the 12 clock
pulses
and to execute the one charcter it takes 32 clock pulses .so it is divided.

Is This Answer Correct ?    9 Yes 8 No

Post New Answer

More Instrumentation Interview Questions

A RANGE OF TRANSMITTER IS (0-400)B mm abs what is "B"?

1 Answers   HCL,


Is that Speed Probe and Vibration Probe sensors are same,if yes what is the diff b/w them?

2 Answers  


hi i am eswar i want to know the instrumentation interview questations for eil(engineers india ltd) i have applied for engineer post in eil please help in this.my mail id eswar310@gmail.com

0 Answers  


Consider a level troll. i am getting a correct value in 4mA and 20mA. the value in the middle(30 to 60%)is disturbed and i am not getting the appropriate value. what is the solution to normalize the level and to get the correct value..

2 Answers   KNPC,


what master plc do?

2 Answers   ISRO, Yokogawa,






A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?

0 Answers  


what is disadvantage of field bus (ff)type of instrument

1 Answers  


how many pulses are required by a ac induction servo motor of 4 poles with 50 Hz frequency to rotate by 1 degree?

0 Answers   United Phosphorus,


what is maximum vaccume?

4 Answers  


why fuse block is not used for AI signal?

0 Answers  


What are the problems faced while testing HART instruments?

1 Answers   SSC,


where are following valves are applicable to install. can any valve be installed any line. globe valve butterfly valve boll valve gate valve

0 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)