we all know that in transformer, voltage and current are inversely related i.e. Vp/Vs= Is/Ip....so in standard CT..we have a ratio of 200/5...that means our voltage should increase by ratio of 40..althoug that is not the case...because that requires high insulation level.and pratically not feasible......can anybody clarify my ques.......thanx
2 3264what is the Excaste meaning of CT Saturation?? 10 P 20, 15 VA, what is the meaning of 10, & 20. if the CT polarrity changed what will happened?? what is the differece between measuring CT & Protection CT?? what is the Saturation Point of measuring CT & Protection CT??
1 10631Is it possible to import & export power through the same power transformer? what will be the vector group normally for both different or same?
1 3198I have 2 KW electric water heater.I am gonna use it in controlling water temp.so I needed to increase or decrease the heating capacity.is there any electrical-electronic circuit for varying the resistance & so current?
1 2575we have 400kv/6.6kv transformer ,it has total 9 taps on HV side with normal tap on tap no 5.when we took the ratio test we observed that ratio was decreasing from tap 1 to tap 5 and was found increasing from tap 5 to tap 9.What is the reason?if anyone have related document then please send me on the email id ankushbahale@gmail.com......plz plz
1 3221whycircuit breaker is not connected at the generator end where the capacity of the generator is more say 60MW, 100MW etc.
2 5647Post New Electrical Engineering Questions
what is alluminium arm in ab conductors
is that a problem if i connect a single phase load to a secondry delta connected transformer but i get a neutral from other transformer i the system?
I am designing new project sub station with 220 kV / 11 kV, 40 MVA capacity. This project have many recifier sets, which can generate 3rd harmonics. Now I have to select vector group of This transformer. To minimise 3rd harmonics, what care should I take in selection of Transformer Vecrtor group? If it is Y-Y with open Delta tertiary then what should be the rating & voltage of Tertiary Winding?
how to copy from plc ge fanuc versamax series,all input and output, adress, and printout.
What is synchro?
Define cuttoff frequency?
hello everybody. what does an abnormal stator winding impedance or dc resistance show? thanx
Why power factor should not be in leading (capacitive) mode of any load.
r we are using in gas turbine mark (5) frame (6) (made in india Bhel 1997) Ā
a simple c++ program to calculate simple interst with its data members as private
What happens if we run alternator on under frequency?
diameter of cable and core is doubled then the value of capacitance is
How Can You Relate Power Engineering With Electrical Engineering?
please explain how to do 'pole drop test' on generator?
we use 400/5A ct and 35/roor3KV,/0.1/root3KV,0.1/root3KV pt ratio. What is the multiple factor of this meter.