Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

which fault current is maximum: 3 phase short circuit, LG, LL or LLG?? why?? in one of the problems that i have solved, 3 phase short circuit current on an unloaded generator came out to be less than the LG fault current. can anybody please explain why.

Bhel,

2 11021

Sir I want questions for rrb sec technician gr III (electrical)

RRB,

1 5849

wat is the difference between BE &BTECH.

8 12766

what is meant by ceiling voltage, ceiling current?? pl reply asap

4 24130

How regulator control the fan speed?

4 24112

i need bhel question papers.

Bhel,

5 12176

generaly all power generating devices is expressed in KVA or MVA then why power ststion is expressed in MW

6 14073

why skin effect is decreases with decrease with frequency? why skin effect occur

Kirloskar,

5 15886

Can anyone tell me how a 12v battery is transformed to 20,000v at the spark plug

6 17278

What is the difference between reciprocating & rotary motors in AC units, which is the best one in terms of operation.

MacLellan,

2 12591

how to select cable size?

7 24028

what is the different betweem earthing and neutral?

8 13387

what is the term of desruptive voltage

Bhel, Energy Infratech,

5 10877

can induction motor run over the rated speed ?

ACC,

12 18265

Using 11000V/433V,3 ph,50Hz,500 KVA, what is the maximum capacity of motor in KW that can be connected and started at a single moment? Also explain about any calculations and formulas used in deriving the same.

4 8183


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

What is polar plot?

1176


What are conduct on the testing in cf in ur site?

1669


Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1.  H1-H2 = H2-H3 H3-H1 2.  H2-H3 = H3-H1 H1-H2 3.  H3-H1 = H1-H2 H2-H3 For the LV side also: 4.  X1-X0 = X2-X0 X3-X0 5.  X2-X0 = X3-X0 X1-X0 6.  X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0  H2-H0  H3-H0    X0-X1  X0-X2  X0-X3 128.0  119.9  7.2      29.2   13.3   15.8 70.7   128.4  59.2     23.4   22.0   3.6 7.2    120.1  128.1    13.4   29.3   15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?

1867


Dear sir, I completed DECE In the year 1995.Now i am working in a private company from last 10 years as an Electrical supervisor.The company having a 1000 KVA transformer.Now i try to apply "C" Licence. I am eligible or not.If not eligible,pls give solution.

1753


Why it is necessary to isolate fire fighting when you are taking shutdown for lv board.

1634


How to decide CT & PT ratings for a given transmission line carrying some rated voltage?

2332


what kn of disc is used in 33kv,132kv,220kv,400kv,800kv transmission line

3287


why the colour of insultor stack , petticoat is brown. Is it has some technical reason.

2024


3 shows a 415 V, 3-phase generator supplying a 3-phase 415/110 V transformer. Draw the individual and combined impedance diagrams to a base of 10 kVA. Determine the system fault kVA and the fault currents at the 415 V and 110 V busbars for short circuit faults on the transformer input or output terminals. Work in p.u. values of impedances.

2659


How can calculate the earthing strip of Copper/GI for rating of 30kV,discharge current 10KA Lightning arrester.

2326


When calculating the speed of a rotor required for a particular frequency of synchronous generator we use the equation 60f/p Is this p is the number of pole pairs of rotor & do we consider the number of pole pairs in the stator is 1?

2009


if we have 320KVA Genset kindly advice how much load we can put it.

1529


which cable is used for 15 Hp monoblock pump 3phase and service wire Distance is 210 feet please tell me cable size Armaured

1582


List the advantages of star-delta starter with induction motor?

1011


Why temperature rise is conducted in bus bars and isolators?

1338