Engineering AllOther (1379) what is mean by busbar and what is the difference between busbar,transmissionline,feeder,distribution line
5731I hv a question regarding power factor improvement just after transformer. I request you to reply me plzz. thank you sir. My friend has a small unit of fabrication. in his factory the main load is a welding machine, lathe machine, grinding machine. this load is not continuous type. now our electricity board has installed 16 KVA, 11000/433 V transformer for our factory. In the energy meter (trivector meter) at LV side of transformer, i hv seen power factor value of 0.15 only when only 3 KW load was flowing. Further electricity board has suggested to install 4 KVAR capacitor at LV side after energy meter. Now my question is that if we permanantly install and switch on 4 KVAR capacitor after energy meter, during some load on transformer and also without any load on transformer, wht will be the power factor shown in energy meter?i dont want to get any penalty by electricity board, so plz suggest me if i can permanantly install and switch on the 4 kvar capacitor or not at LV side of transformer just after energy meter? Thank you again and awaiting for ur positive reply soon.
9 12924Why converter duty transformer neutrals are not earthed...i am still not sure if this question is also correct...Please email at ranjan120482@gmail.com
2390How to decide the rating of CBCT? We have 6.6Kv switchgear & having 50/1 cbct ,i want to know how this 50/1 A came? On what basis we decide CBCT reting?
1 8885What is difference between Step Up Transformer & Booster Transformer? can we used instead of any one?
CS,
2 17768Difference Between Differential Relay and Restricted Earth Fault Relay of Power Transformers
KSEB,
1 11566
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
Good evening all I need a small favour regarding reliance paper i wanna probable sample papers(e&i) of reliance. if any of u have any idea about dis then plz mail me back.i belongs to electronics and instrumentation engg.so i need e&i papers. thanking u....
which fit is this 177-S6?
i want to know the syllabus for management trainee exam,vizag steel plant,2009
please send me rrb gorakhpur je teli question paper
pls send me model paper of NPCIL for executive trainee. and syllabus of executive trainee 2015.
pls mail some more tecnical qustions at msaranya2610@gmail.com
i am a student of thapar university final year.can anybody please help me with the exam pattern of the companies:engineers india ltd. ; iocl ; UOP, HPCL. If psbl plz send me the previous years questions on this email id k_arora1987@yahoo.com. i d be really greatful
what is the difference between replacement of cement by groundnut shell ash
send interview questins about pro_e to me mohanrvs_1984@yahoo.co.in
please send me bhel questions on rupesh.017@rediffmail.com
consiteunts of indian railways
when will be the iocl interview results i faced interview on 8th september 2008 iam from electrical branch i faced interview for the post of electrical engineer??????????????????????//
Explain the approximate cost of the following corrosion monitoring systems. Smart pebbles eci-1(embedded corrosion instrument) monitoring cables time domain reflectometry &corrosion penetration monitoring system(cpmp)?
two way ckt diagram can be drawn by how many ways? give diagram