Engineering AllOther (1379) What will happened if the neutral of secondary of Xformer ( Star point) Note it's above KVA rated Xformer
1889In india, according to trade theory above 5 HP motor reqired star delta starter. But we R connect 11 KV motor with 14MW in Direct to line ( With VCB starter combination) Can U Guess, How it is possible ?????
2145If we have a 2000kva load,How much kvar capacitors we go to add to improve the power factor at 0.9?pls give the calculation and fully theory?
2 7423Why not connect impeller shaft directly to motor shaft bypassing the stuffing box?What is the purpose stuffing box? Is there any pressure on the stuffing box?
2 5254How many types of Differential protection are there? and what the special arrangement are made at the time of charging of a transformer on the Differential protection?
1 2870
What is the minimum rating availalbe for weld neck orifice in market?
Why we used 690V in ACS 800 drives.Why dont use standard voltage like 415v or 1.1Kv
In tower foundation, on the time of 3 mtr pit RCC casting if water and mud is their surface of PCC then what will be do?
how to calculate load bearing column
How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.
WHAT DLC DESIGN IN CONSTRUCTION
I an doing Engineering in IT(4th year). i want to know what is the scope or .NET and Linux, and which is better for carrier
What is the function of AUTO SHUT OF Valve in Diesel Engine?
What is the de rating factor of cable? What is the importance of the de rating factor in cable select
What are orthotropic materials ?
State some kingpin offset application?
Explain counter sample.
what is the difference between directional & non directional earth fault with example please explain.
how can i find cable size from current rating?
Cooling water line sizing ?