Is SmartPlant Instrumentation taking advantage of the
quality assurance procedures within Intergraph?



Is SmartPlant Instrumentation taking advantage of the quality assurance procedures within Intergra..

Answer / guest

Yes. SmartPlant Instrumentation is certified using the same
tools and procedures Intergraph develops and uses to ensure
top quality products.

Is This Answer Correct ?    3 Yes 0 No

Post New Answer

More Instrumentation Interview Questions

ON RADAR INTERFACE LEVEL TRANSMITTER IF DI-ELECRIC IS WRONG WITH CONTINIUS PROCESS THAN HOW CAN INDENTIFY OR HOW CAN I PUT NEW DI-ELECTRIC VALUE?(ROSEMOUNT-TDR-3300-COXIAL PROBE TYPE)

1 Answers   Chevron Phillips,


What inherent design and operating principles are included in a modern control system to use predictive maintenance practices to increase overall system reliability?

1 Answers  


how to install the Ph and Conductivity analyser? is there are any procedures which has to be maintained.

2 Answers  


what is the meaning of HART ?

2 Answers  


I have a LT of 10000mmwc range. can i use this LT in 1000mmwc range of tank?? if yes than what happened???

3 Answers   Nirma,


while am calibrating Drager polytron 2IR flame gas detector occured non zero status.how can i get zero status?

1 Answers   Gasco,


Calculate the maximum pressure drop that can be allowed to occur across a control valve, so that we can prevent cavitation / flashing from occurring. Use the following formula: Δ P allow = Km (P1 – PvapourA) where, Δ P allow - the maximum allowable differential pressure for sizing purposes, or terminal pressure drop; Km- the valve recovery coefficient from the manufacturer’s catalogue; P1 - absolute inlet fluid pressure; PvapourA - absolute fluid vapour pressure at the inlet temperature; Use Atmospheric pressure = 101.3 kPa, P1 = 1200 kPa(g), PvapourA = 4 kPa, KM = 0.72

1 Answers  


can u briefly explain aboutan aryton shunt multirange DC ammeter?

1 Answers  


what is mean by TDC-3000

5 Answers   ADCO,


What is zener diode? What is voltage regulator?

1 Answers  


the whole paper was based on Transducers..questions like define repeatability, error,accuracy,precision..den there were many q. on the conversion of Pa to mmHg and other units.. also..der wer few Q. on some level sensors(with diagram)

1 Answers   GNFC,


Coriolis flow meter coil supply is 24vdc but why still we given 230ac for this transmitter let me explained detailed review please

1 Answers   Shell,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4453)
  • Electrical Engineering Interview Questions Electrical Engineering (16638)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)