Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Why we didn’t feel electric shock in an electric train ??

Answers were Sorted based on User's Feedback



Why we didn’t feel electric shock in an electric train ??..

Answer / prasad

because railway track acts as a earth conductor-return path

Is This Answer Correct ?    33 Yes 13 No

Why we didn’t feel electric shock in an electric train ??..

Answer / avinash

Electricity is harnessed from the overhead lines by the
Pentagraph. The Pentagraghs are insulated.The insulators
are placed between the high tension wires and the train
coach.

Is This Answer Correct ?    22 Yes 5 No

Why we didn’t feel electric shock in an electric train ??..

Answer / sathiarajan

Electric train is a floating system & there is no common
ground. So at any cost the circuit can not completed
through the human body. So we can not feel any shock

Is This Answer Correct ?    31 Yes 15 No

Why we didn’t feel electric shock in an electric train ??..

Answer / haresh

Because electricity is only passes through the conductors
which are not in touch to coaches of train, electricity
only passes through conductors to the generators, batteries
and all lighting equipments as we use it at our home. So no
feel of electrict shock in an electric train.

Is This Answer Correct ?    33 Yes 19 No

Why we didn’t feel electric shock in an electric train ??..

Answer / kaji mustufa

As the source used in trains is from overhead lines and it makes contact with PENTOGRAPH contactor but pentograph contactor is insulated from coaches by mounting insulator discs on the top of train..
summerising, electric train and source (i.e. 25kV dc) is electricaly not connected.. Hence no shock....

Is This Answer Correct ?    7 Yes 2 No

Why we didn’t feel electric shock in an electric train ??..

Answer / vipul dhruv

dear avinash its not pentagraph its pantograph....

Is This Answer Correct ?    10 Yes 6 No

Why we didn’t feel electric shock in an electric train ??..

Answer / vijay salaskar

Dear Hemant bhai
Ac current have symbolic represebtation ofsin wave where the current go to its min value and max value due to which at minimum point ac current leave the person
But in dccurrent it continuosly supply curent so there is chance of get shock in dc current
So kindly understand this

Is This Answer Correct ?    1 Yes 0 No

Why we didn’t feel electric shock in an electric train ??..

Answer / ashish mishra

because the coches are not electrically conected to the
current carring wires .

Is This Answer Correct ?    10 Yes 10 No

Why we didn’t feel electric shock in an electric train ??..

Answer / bibin

The electric train is well insulated from its electrical system

Is This Answer Correct ?    0 Yes 0 No

Why we didn’t feel electric shock in an electric train ??..

Answer / hemant

because AC is converted into DC and in DC we don't get shock

Is This Answer Correct ?    5 Yes 138 No

Post New Answer

More Electrical Engineering Interview Questions

Why are the cores of large transformers built up of circular transactions ?

0 Answers  


how to make an earthing certificate

0 Answers  


how do the stepper motor works.

1 Answers   Vardhman,


what is the formula for computing cable tray size & capacity

0 Answers  


what is principle of DG

5 Answers  


temp of cast resin 1500kva tx formerwent up to 138.c but came down very fast to about 100.c within 20 mins when load was reduced from 70% to 60%

0 Answers  


in most industies hormonics present up to some level. what is limit ? and there effect?

4 Answers   Bhel,


In a panel 2500A ACB is the incoming breaker then what is the size of the bus bar?

1 Answers  


plz tell me the potential difference between phase and netrul

2 Answers   CGL,


what is the diffrence between mcb &elcb?

2 Answers   Kahramaa, Synergy,


Best way to measure the Soil resistance of rocky soil, three probe method and four probe method

0 Answers  


What is the formula to find out cross sectional area of cable for certain current rating?

1 Answers   MRF,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)